40
12.12 e-ion Operation
Purpose
o
This operation provides clean air by producing negative ions to attract dust captured at the positively charged
e-ion filters.
Control
condition
o
e-ion operation start condition
During unit running at any operation mode, if “e-ion” button is pressed, combination operation (operation
mode + e-ion operation) starts.
During unit is OFF, if “e-ion” button is pressed, e-ion individual operation starts.
o
e-ion operation stop condition
When “OFF/ON” button is pressed to stop the operation.
When “e-ion” button is pressed again.
When “PATROL” button is pressed.
When OFF Timer activates.
o
e-ion operation pause condition
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after
indoor fan restarts.
When indoor intake temperature
≥
40°C. e-ion operation resume after indoor intake temperature < 40°C
continuously for 30 minutes.
Control
Content
o
Indoor
fan
control
During any operation mode combines with e-ion operation, fan speed follows respective operation mode.
During e-ion individual operation - only Auto Fan Speed and no Powerful operation is allowed. Even if
Fan Speed button is pressed, no signal is sent to air conditioner, and no change on LCD display.
Auto Fan Speed for e-ion operation switches between HLo and CLo at pattern below:
o
Airflow direction control
During any operation mode combines with e-ion operation, airflow direction follows respective operation
mode.
During e-ion individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
signal is sent to air conditioner, and no change on LCD display.
Summary of Contents for CS-QE12MKE
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit ...
Page 14: ...14 5 2 Outdoor Unit ...
Page 15: ...15 6 Refrigeration Cycle Diagram ...
Page 16: ...16 7 Block Diagram ...
Page 17: ...17 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 18: ...18 8 2 Outdoor Unit ...
Page 19: ...19 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 20: ...20 9 2 Outdoor Unit ...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 22: ...22 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 24: ...24 10 2 Outdoor Unit ...
Page 52: ...52 15 3 Error Code Table ...
Page 53: ...53 ...
Page 80: ...80 16 1 3 To remove discharge grille ...
Page 81: ...81 16 1 3 1 To remove control board 16 1 4 To remove cross flow fan and indoor fan motor ...
Page 82: ...82 ...
Page 84: ...84 17 Technical Data 17 1 Operation Characteristics 17 1 1 CU QE9MKE ...
Page 85: ...85 ...
Page 86: ...86 ...
Page 87: ...87 ...
Page 88: ...88 17 1 2 CU QE12MKE ...
Page 89: ...89 ...
Page 90: ...90 ...
Page 91: ...91 ...