83
(Note)
• All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488).
• “O” marked parts are recommended to be kept in stock.
REF. NO.
PART NAME & DESCRIPTION
QTY.
CU-PC12MKF
REMARK
1
CHASSIS ASS’Y
1
CWD50K2088
2
SOUND PROOF MATERIAL
1
CWG302110
3
FAN MOTOR BRACKET
1
CWD541030
4
SCREW - FAN MOTOR BRACKET
2
CWH551217
5
FAN MOTOR
1
CWA951676
O
6
SCREW - FAN MOTOR MOUNT
4
CWH55406J
7
PROPELLER FAN ASS’Y
1
CWH03K1006
8
NUT - PROPELLER FAN
1
CWH56053J
9
COMPRESSOR
1
2KS210D5AA06
O
10
ANTI - VIBRATION BUSHING
3
CWH50055
11
NUT - COMPRESSOR MOUNT
3
CWH561049
12
CONDENSER
1
CWB32C2821
13
CAPILLARY TUBE ASS’Y
1
CWB15K1165
14
STRAINER
1
CWB111011
15
HOLDER COUPLING
1
CWH351023
16
2-WAY VALVE (LIQUID)
1
CWB021362
O
17
3-WAY VALVE (GAS)
1
CWB011482
O
20
TERMINAL COVER
1
CWH171012
21
NUT - TERMINAL COVER
1
CWH7080300J
22
SOUND PROOF BOARD
1
CWH151023
23
TERMINAL BOARD ASS’Y
1
CWA28K1064J
24
CAPACITOR - COM.
1
F0GAH356A001
O
25
HOLDER CAPACITOR
1
CWH30060
26
CAPACITOR - F.M
1
DS441205NPQA
O
27
CABINET SIDE PLATE
1
CWE041248A
28
CABINET SIDE PLATE COMPLETE
1
CWE04C1118
29
CABINET FRONT PLATE ASS’Y
1
CWE06K1034
30
CABINET TOP PLATE
1
CWE031014A
31
CONTROL BOARD COVER COMP
1
CWH13C1064
32
PLATE - C.B.COVER TERMINAL
1
CWH131295
33
WIRE NET
1
CWD041111A
Summary of Contents for CS-PC12MKF
Page 10: ...10 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 11: ...11 5 Dimensions 5 1 Indoor Unit 5 1 1 CS PC12MKF ...
Page 12: ...12 5 1 2 CS PC18MKF CS PC24MKF ...
Page 13: ...13 5 2 Outdoor Unit 5 2 1 CU PC12MKF CU PC18MKF ...
Page 14: ...14 5 2 2 CU PC24MKF ...
Page 15: ...15 6 Refrigeration Cycle Diagram ...
Page 16: ...16 7 Block Diagram 7 1 CS PC12MKF ...
Page 17: ...17 7 2 CS PC18MKF CS PC24MKF ...
Page 21: ...21 9 Electronic Circuit Diagram 9 1 CS PC12MKF CU PC12MKF ...
Page 22: ...22 9 2 CS PC18MKF CU PC18MKF ...
Page 23: ...23 9 3 CS PC24MKF CU PC24MKF ...
Page 25: ...25 10 1 1 2 CS PC18MKF CS PC24MKF ...
Page 32: ...32 11 2 5 Wire Stripping And Connecting Requirement ...
Page 56: ...56 16 1 1 3 To remove Discharge Grille ...
Page 57: ...57 16 1 1 4 To remove Control Board 16 1 1 5 To remove Cross Flow Fan and Indoor Fan Motor ...
Page 58: ...58 ...
Page 60: ...60 16 2 1 3 To remove Discharge Grille ...
Page 61: ...61 16 2 1 4 To remove Control Board 16 2 1 5 To remove Cross Flow Fan and Indoor Fan Motor ...
Page 62: ...62 ...
Page 63: ...63 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 71: ...71 17 4 Cooling Capacity Performance Data CS CU PC12MKF 220V ...
Page 72: ...72 CS CU PC12MKF 240V CS CU PC18MKF 220V ...
Page 73: ...73 CS CU PC18MKF 240V ...
Page 74: ...74 CS CU PC24MKF 220V ...
Page 75: ...75 CS CU PC24MKF 240V ...
Page 76: ...76 17 5 Sound Data CS PC18MKF ...
Page 77: ...77 CS PC24MKF ...