![Panasonic CS-PC12MKF Service Manual Download Page 45](http://html.mh-extra.com/html/panasonic/cs-pc12mkf/cs-pc12mkf_service-manual_1507887045.webp)
45
12.11. ECONAVI & AUTO COMFORT Operation
• A Pyoelectric infrared sensor is used to detect injection strength variation of infrared at setting area to determine
the presence or absence of human and its activity level. Human detection area is shown in figure below:
• ECONAVI & AUTO COMFORT Sensor abnormality detection
1. Connnector pulled out (disconnected), Wire cut Abnormality (Fix Output at Hi)
a. Abnormal judgment start condition.
Start from ECONAVI & AUTO COMFORT Sensor power ON, and end after 30 seconds.
b. Control content.
Judge ECONAVI & AUTO COMFORT Sensor power level every 100ms.
c. Abnormal Judgment condition.
When ECONAVI & AUTO COMFORT Sensor has continues for 25 seconds Hi level.
2. Circuit Abnormal (Fix Output Lo)
a. Abnormal judgment start condition.
After ECONAVI & AUTO COMFORT Sensor unit power ON, and after pressed 70 seconds.
b. Control content.
Judge ECONAVI & AUTO COMFORT Sensor power level every 100ms.
c. Abnormal Judgment condition.
When ECONAVI & AUTO COMFORT Sensor has continues at Lo level for 25 seconds.
3. Abnormal treatment
Any one of the above self-diagnosis result is abnormal
• Abnormal c1 and ECONAVI & AUTO COMFORT Sensor power supply OFF.
• After ECONAVI & AUTO COMFORT Sensor unit power is OFF for 5 seconds, Retry the ECONAVI & AUTO COMFORT
operation.
• When Abnormal counter reach 4 counts, ECONAVI & AUTO COMFORT sensor abnormality is confirmed.
(Abnormal counter is cleared when sensor power ON and maintain normal for 120 seconds and above or Clear Anormal
counter by
power reset)
• Save ECONAVI & AUTO COMFORT Sensor Abnormality (no Timer LED blinking).
• ECONAVI & AUTO COMFORT Sensor operation OFF, but ECONAVI & AUTO COMFORT LED maintain ON.
• The unit still operate as normal.
• Sensor error counter can be cleared only after power supply reset or AC Reset button on the remote control is pressed.
• ECONAVI & AUTO COMFORT operation – Human presence/absence detection outlined flow
Process infrared sensor output signal
Human detection (movement) every 3 seconds.
Human detection records
Records human detection (movement) result for 30 seconds and determine its activity level i.e. Hi/Lo.
Presence / absence detection
Compares current and previous human detection result every 30 seconds to determine the presence
or absence of human.
Presence / absence determination
Based on human presence / absence detection, if human presence detection showed within 30
minutes, it is recognised that human is present. If human absence detection showed continuously for
more than 30 minutes, it is recognised that no human is present.
Summary of Contents for CS-PC12MKF
Page 10: ...10 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 11: ...11 5 Dimensions 5 1 Indoor Unit 5 1 1 CS PC12MKF ...
Page 12: ...12 5 1 2 CS PC18MKF CS PC24MKF ...
Page 13: ...13 5 2 Outdoor Unit 5 2 1 CU PC12MKF CU PC18MKF ...
Page 14: ...14 5 2 2 CU PC24MKF ...
Page 15: ...15 6 Refrigeration Cycle Diagram ...
Page 16: ...16 7 Block Diagram 7 1 CS PC12MKF ...
Page 17: ...17 7 2 CS PC18MKF CS PC24MKF ...
Page 21: ...21 9 Electronic Circuit Diagram 9 1 CS PC12MKF CU PC12MKF ...
Page 22: ...22 9 2 CS PC18MKF CU PC18MKF ...
Page 23: ...23 9 3 CS PC24MKF CU PC24MKF ...
Page 25: ...25 10 1 1 2 CS PC18MKF CS PC24MKF ...
Page 32: ...32 11 2 5 Wire Stripping And Connecting Requirement ...
Page 56: ...56 16 1 1 3 To remove Discharge Grille ...
Page 57: ...57 16 1 1 4 To remove Control Board 16 1 1 5 To remove Cross Flow Fan and Indoor Fan Motor ...
Page 58: ...58 ...
Page 60: ...60 16 2 1 3 To remove Discharge Grille ...
Page 61: ...61 16 2 1 4 To remove Control Board 16 2 1 5 To remove Cross Flow Fan and Indoor Fan Motor ...
Page 62: ...62 ...
Page 63: ...63 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 71: ...71 17 4 Cooling Capacity Performance Data CS CU PC12MKF 220V ...
Page 72: ...72 CS CU PC12MKF 240V CS CU PC18MKF 220V ...
Page 73: ...73 CS CU PC18MKF 240V ...
Page 74: ...74 CS CU PC24MKF 220V ...
Page 75: ...75 CS CU PC24MKF 240V ...
Page 76: ...76 17 5 Sound Data CS PC18MKF ...
Page 77: ...77 CS PC24MKF ...