12.12.1.6 Sunlight Sensor Abnormality
•
Abnormality
detection:
o
When ECONAVI is ON, if the sunlight intensity value below minimum level continuously for 24 hours, the
sunlight sensor disconnection error counter will increase by 1 time. If the ECONAVI is OFF, the 24 hours
timer will be reset, but the sunlight sensor disconnection error counter will not be reset.
•
Error Code judgment
o
When sunlight sensor disconnection error counter reached 15 times, H70 occurred.
o
No TIMER indicator or ECONAVI indicator blinks.
•
When error code happened, the unit is able to operate without sunlight sensor.