16.2. Sensible Capacity Chart
O
CS-HE9GKE CU-HE9GKE
O
CS-HE12GKE CU-HE12GKE
230V
Outdoor Temp. (
°
C)
Indoor wet
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
°
C
2.58
1.96
0.47
2.41
1.88
0.50
2.24
1.80
0.54
2.04
1.71
0.58
19.0
°
C
2.60
0.51
19.5
°
C
2.83
2.05
0.48
2.65
1.97
0.51
2.46
1.89
0.55
2.24
1.80
0.59
22.0
°
C
3.09
2.12
0.48
2.88
2.04
0.52
2.68
1.97
0.56
2.44
1.88
0.60
230V
Outdoor Temp. (
°
C)
Indoor wet
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
°
C
3.47
2.63
0.78
3.24
2.52
0.84
3.02
2.43
0.90
2.74
2.30
0.97
19.0
°
C
3.50
0.85
19.5
°
C
3.81
2.76
0.79
3.56
2.65
0.85
3.31
2.55
0.91
3.01
2.43
0.98
22.0
°
C
4.15
2.86
0.81
3.88
2.75
0.87
3.61
2.65
0.93
3.28
2.53
1.00
TC
SHC
IP
-
-
-
Total Cooling Capacity (kW)
Sensible Heat Capacity (kW)
Input Power (kW)
Indoor 27
°
C/19
°
C
Outdoor 35
°
C/24
°
C
Summary of Contents for CS-HE12GKE
Page 10: ...10 5 Dimensions 5 1 Indoor Unit ...
Page 11: ...11 5 2 Outdoor Unit ...
Page 12: ...12 6 Refrigeration Cycle Diagram ...
Page 13: ...13 7 Block Diagram ...
Page 14: ...14 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 15: ...15 8 2 Outdoor Unit ...
Page 16: ...16 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 17: ...17 9 2 Outdoor Unit ...
Page 19: ...19 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Page 20: ...20 ...
Page 27: ...27 4 Attach the control board cover back to the original position with the screw ...
Page 57: ...57 16 Technical Data 16 1 Operation Characteristics 16 1 1 CS HE9GKE CU HE9GKE ...
Page 58: ...58 ...
Page 59: ...59 ...
Page 60: ...60 ...
Page 61: ...61 16 1 2 CS HE12GKE CU HE12GKE ...
Page 62: ...62 ...
Page 63: ...63 ...
Page 64: ...64 ...