39
12.2.3.2. Outdoor Air Temperature Control
• The maximum current value is regulated when the outdoor air temperature rises above 14
°
C in order to avoid compressor over-
loading.
12.2.3.3. Overload Protection Control
• The compressor operating frequency is regulated in accordance to indoor heat exchanger temperature as shown in below.
• If the heat exchanger temperature exceeds 60°C, compressor will stopped.