35
12.1.13. ON Timer Control
ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to provide a
comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine the
indoor intake air temperature and outdoor air temperature in order to judge the operation starting time.
From the judgment, the decided operation will start operate earlier than the set time as shown below.
12.1.14. OFF Timer Control
OFF timer can be set using remote control, the unit with timer set will stop operate at set time.
12.1.15. Auto Restart Control
1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four
minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after
power supply resumes.
2. This type of control is not applicable during ON/OFF Timer setting.
12.1.16. Indication Panel
Note:
• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode judgement,
or ON timer sampling.
• If Timer LED is blinking, there is an abnormality operation occurs.
LED
POWER
TIMER
QUIET
POWERFUL
Color
Green
Orange
Orange
Orange
Light ON
Operation ON
Quiet Setting ON
Quiet Mode ON
Powerful Mode ON
Light OFF
Operation OFF
Quiet Setting OFF
Quiet Mode OFF
Powerful Mode OFF
Summary of Contents for CS-HE12GKE
Page 10: ...10 5 Dimensions 5 1 Indoor Unit ...
Page 11: ...11 5 2 Outdoor Unit ...
Page 12: ...12 6 Refrigeration Cycle Diagram ...
Page 13: ...13 7 Block Diagram ...
Page 14: ...14 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 15: ...15 8 2 Outdoor Unit ...
Page 16: ...16 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 17: ...17 9 2 Outdoor Unit ...
Page 19: ...19 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Page 20: ...20 ...
Page 27: ...27 4 Attach the control board cover back to the original position with the screw ...
Page 57: ...57 16 Technical Data 16 1 Operation Characteristics 16 1 1 CS HE9GKE CU HE9GKE ...
Page 58: ...58 ...
Page 59: ...59 ...
Page 60: ...60 ...
Page 61: ...61 16 1 2 CS HE12GKE CU HE12GKE ...
Page 62: ...62 ...
Page 63: ...63 ...
Page 64: ...64 ...