![Panasonic CS-E24DKE Service Manual Download Page 67](http://html.mh-extra.com/html/panasonic/cs-e24dke/cs-e24dke_service-manual_256896067.webp)
DISPOSAL OF OUTDOOR UNIT DRAIN WATER
•
If a drain elbow is used, the unit should be placed on a
stand which is taller than 3 cm.
•
If the unit is used in an area where temperature falls below
0°C for 2 or 3 days in succession, it is recommended not to
use a drain elbow, for the drain water freezes and the fan
will not rotate.
CHECK THE DRAINAGE
•
Open front panel and remove air filters.
(Drainage checking can be carried out without removing the
front grille.)
•
Pour a glass of water into the drain tray-styrofoam.
•
Ensure that water flows out from drain hose of the indoor
unit.
EVALUATION OF THE PERFORMANCE
•
Operate the unit at cooling operation mode for fifteen
minutes or more.
•
Measure the temperature of the intake and discharge air.
•
Ensure the difference between the intake temperature and
the discharge is more than 8°C.
Is there any gas leakage at flare nut connections?
Has the heat insulation been carried out at flare nut
connection?
Is the connecting cable being fixed to terminal board firmly?
Is the connecting cable being clamped firmly?
Is the drainage OK?
(Refer to “Check the drainage” section)
Is the earth wire connection properly done?
Is the indoor unit properly hooked to the installation plate?
Is the power supply voltage complied with rated value?
Is there any abnormal sound?
Is the cooling operation normal?
Is the thermostat operation normal?
Is the remote control’s LCD operation normal?
Is the super alleru-buster filter is installed?
11.3.6. PIPE INSULATION
1. Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap
the insulated piping end to prevent water from going inside the piping.
2. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E FOAM
with thickness 6 mm or above.
CHECK ITEMS
67
CS-E24DKE CU-E24DKE
Summary of Contents for CS-E24DKE
Page 9: ...4 Dimensions 4 1 Indoor Unit Remote Control 9 CS E24DKE CU E24DKE ...
Page 10: ...4 2 Outdoor Unit 10 CS E24DKE CU E24DKE ...
Page 11: ...5 Refrigeration Cycle Diagram 11 CS E24DKE CU E24DKE ...
Page 12: ...6 Block Diagram 12 CS E24DKE CU E24DKE ...
Page 13: ...7 Wiring Diagram 13 CS E24DKE CU E24DKE ...
Page 77: ...13 Technical Data 77 CS E24DKE CU E24DKE ...
Page 89: ...89 CS E24DKE CU E24DKE ...
Page 91: ...18 3 Remote Control 91 CS E24DKE CU E24DKE ...
Page 92: ...18 4 Print Pattern Indoor Unit Printed Circuit Board 92 CS E24DKE CU E24DKE ...
Page 94: ......