![Panasonic CS-E24DKE Service Manual Download Page 37](http://html.mh-extra.com/html/panasonic/cs-e24dke/cs-e24dke_service-manual_256896037.webp)
2. Auto Fan Speed
Note:
a. UP:
•
If move from Lo, the fan speed will be shifted to Maximum 1300 rpm (E24DK).
•
If move from Maximum, the fan speed no change.
•
In up zone, 10 rpm is added for every 10s until Maximum 1300 rpm (E24DK).
b. DOWN:
•
The fan speed will be decreased one step every 10 sec. until Minimum 1100 rpm.
c.
Current Output Fixed:
•
Maintain at present fan speed.
d. Instantaneous Maximum:
•
Fan speed will be increased to maximum auto fan speed.
e. Temperature in ( ) is for Powerful Mode operation.
8.2.3.2. Intake Air Temperature Control
Compressor will operate at freq 67 Hz if either one of the below conditions occur:
1. When the indoor intake air temperature is above 10°C and remote control setting fan speed is lower Me-.
2. When the indoor intake air temperature is 30°C or above.