8.1.18. Ionizer Operation
8.1.17. Indoor Power Relay Control
Power relay will turn on during operation or in progress of stopping operation. Although operation stops, the power relay continues
on for three minutes.
However, during instantaneous power failure (< 0.5s), power relay will turn off. Then, it will turn on 2 minutes after power recover
and the unit will operate as previous operation condition.
Purpose
To provide fresh air effect to users by discharging minus ion to air.
Control Condition
a. Ionizer Only Operation.
1. When air-conditioner unit is at “OFF” condition (standby) and ION operation button at remote control is pressed.
Fan & ionizer on, ION LED illuminates, but power LED maintain off. (1
→
2)
However, fan speed can be adjusted later by customer during this operation.
Airflow direction (Horizontal Vane) control:
Follow vane direction control at cooling mode.
Horizontal vane can be changed by customer during ion only operation.
b. Operation Mode + Ionizer Operation.
1. Ionising Operation Start Condition
When air conditioner unit is in “ON” condition (Heat, Cool, Dry, Auto mode) and ION operation button at remote control is
pressed. Ionizer on & ION LED illuminates. (3
→
4)
Power LED also illuminates.
2. Ionising Operation Stop Condition
When one of the following condition is satisfied, ION operation stops.
a. Stopped by ON/OFF switch.
b. Timer OFF activates.
c.
ION feedback signal shows error.
3. Ionizer operation status is not memorised by micon. After OFF, when operation is “ON” again, air conditioner operates
29
CS-E24DKE CU-E24DKE
Summary of Contents for CS-E24DKE
Page 9: ...4 Dimensions 4 1 Indoor Unit Remote Control 9 CS E24DKE CU E24DKE ...
Page 10: ...4 2 Outdoor Unit 10 CS E24DKE CU E24DKE ...
Page 11: ...5 Refrigeration Cycle Diagram 11 CS E24DKE CU E24DKE ...
Page 12: ...6 Block Diagram 12 CS E24DKE CU E24DKE ...
Page 13: ...7 Wiring Diagram 13 CS E24DKE CU E24DKE ...
Page 77: ...13 Technical Data 77 CS E24DKE CU E24DKE ...
Page 89: ...89 CS E24DKE CU E24DKE ...
Page 91: ...18 3 Remote Control 91 CS E24DKE CU E24DKE ...
Page 92: ...18 4 Print Pattern Indoor Unit Printed Circuit Board 92 CS E24DKE CU E24DKE ...
Page 94: ......