Unit
CS-E18CKE
CU-E18CKE
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
Drain
Hose
Inner diameter
mm
12
—
Length
m
0.65
—
Power Cord Length
Number of core-wire
2.1 m
3 core wires × 1.5 mm
2
—
—
Dimensions
Height
inch (mm)
10 - 13/16 (275)
29 - 17/32 (750)
Width
inch (mm)
39 - 9/32 (998)
34 - 7/16 (875)
Depth
inch (mm)
8 - 9/32 (210)
13 - 19/32 (345)
Net Weight
lb (kg)
24 (11)
108 (49)
Compressor
Type
—
Involute scroll
Motor
Type
—
Brushless (4-pole)
Rated
Output
W
—
900
Air Circulation
Type
Cross-flow Fan
Propeller Fan
Material
ASHT-18
P.P
Motor
Type
Transistor (8-poles)
Transistor (8-poles)
Rate Output
W
30
40
Fan Speed
Lo (Cool/Heat)
rpm
1,150 / 1,270
—
Me (Cool/Heat)
rpm
1,290 / 1,410
—
Hi (Cool/Heat)
rpm
1,440 / 1,560
660
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium (Blue Coated)
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 / 15
2 / 34
FPI
21
16
Size (W × H × L)
mm
810 × 315 × 25.4
849.3
878
× 714 × 36.4
Refrigerant Control Device
—
Expansion Valve
Refrigeration Oil
(c.c)
—
RB68A (360)
Refrigerant (R410A)
kg (oz)
—
1.18 (41.7)
Thermostat
Electronic Control
—
Protection Device
Electronic Control
Electronic Control
Length
mm
—
—
Capillary Tube
Flow Rate
l/min
—
—
Inner Diameter
mm
—
—
Air Filter
Material
Style
P.P.
Honeycomb
—
•
Specifications are subjected to change without notice for further improvement.
7
Summary of Contents for CS-E18CKE
Page 10: ...4 Dimensions 10 ...
Page 11: ...11 ...
Page 12: ...5 Refrigeration Cycle Diagram 12 ...
Page 13: ...6 Block Diagram 13 ...
Page 14: ...7 Wiring Diagram 14 ...
Page 20: ...B Indoor Fan Control i Indoor fan control operation outline 1 Cooling Dry 2 Heating 20 ...
Page 44: ...9 Operating Instructions 45 46 45 46 46 46 46 46 48 49 47 Ionizer DO NOTTOUCH 44 ...
Page 45: ...49 50 48 47 45 ...
Page 47: ...every 6 months see page 44 see page 48 Soaps Neutral household detergents pH7 47 ...
Page 48: ...refer page 47 48 ...
Page 49: ...48 49 ...
Page 51: ...44 46 46 46 47 47 47 48 47 48 45 51 ...
Page 67: ...3 For the embedded piping This can be used for left rear piping left bottom piping also 67 ...
Page 81: ...13 Technical Data 81 ...
Page 82: ...82 ...
Page 96: ...96 ...
Page 98: ...18 1 REMOTE CONTROL 98 ...
Page 99: ...18 2 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD 99 ...
Page 100: ...18 3 PRINT PATTERN OUTDOOR UNIT PRINTED CIRCUIT BOARD VIEW 100 MAICO Printed in Malaysia ...