CompHz = Freq. A × Freq. H + Freq. C
Example Calculation:
Model No.: E18CK
Operation Mode: Cooling
When Intake Air Temperature - Internal setting Temperature:
1.5°C
CompHz
=
Freq. A × Freq. H + Freq. C
=
1.53 × 46 + 2.5
=
72 Hz (It cuts down less than a decimal point)
Cooling & Soft Dry
E18CK
E21CK
Freq. A
Freq. C
Freq. A
Freq. C
Low Load (Freq. H
9)
1.2
5.0
1.7
7.0
High Load (Freq. H > 10)
1.53
2.5
2.0
4.0
Heating
E18CK
E21CK
Freq. A
Freq. C
Freq. A
Freq. C
Low Load (Freq. H
11)
1.6
8.0
1.9
7.0
High Load (Freq. H > 12)
2.2
1.0
2.35
1.0
Freq. Range
E18CK
E21CK
Cooling
Fc
72
96
Operation Range
12 ~ 86
12 ~ 102
Heating
Fh
86
92
Operation Range
14 ~ 128
14 ~ 128
8.1.2. Compressor Operation Frequency
Intake Air Temperature - Internal Setting Temperature (°C)
Freq. H
Zone
Cooling & Soft Dry
Heating
Cooling
Soft Dry
Heating
Remark
1
-2.0
1.5
1
1
1
2
-1.5
1.0
1
1
1
3
-1.0
0.5
14
8
11
4
-0.5
0.0
20
8
15
5
0.0
-0.5
27
8
22
6
0.5
-1.0
35
11
27
7
1.0
-1.5
43
11
36
8
1.5
-2.0
46
11
39
Fc, Fh
9
2.0
-2.5
46
11
39
Fc, Fh
10
2.5
-3.0
46
11
39
Fc, Fh
11
Nil
-3.5
Nil
Nil
39
Fh
12
Nil
-4.0
Nil
Nil
39
Fh
Operating Frequency Calculation Formula:
Remarks:
When Freq. H is equal to 46 (Cooling), 39 (Heating) or above, the Comp. may run at the freq. higher than Fc or Fh up to max.
freq. operation.
Best Amenity Control
Every 90s (Cooling), 120s (Heating) maintain same zone Freq. H + 1 until Fc (46), Fh (39).
8.1.3. Cooling Operation
8.1.3.1. Thermostat control
•
Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C.
•
Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point +0.5°C.
17
Summary of Contents for CS-E18CKE
Page 10: ...4 Dimensions 10 ...
Page 11: ...11 ...
Page 12: ...5 Refrigeration Cycle Diagram 12 ...
Page 13: ...6 Block Diagram 13 ...
Page 14: ...7 Wiring Diagram 14 ...
Page 20: ...B Indoor Fan Control i Indoor fan control operation outline 1 Cooling Dry 2 Heating 20 ...
Page 44: ...9 Operating Instructions 45 46 45 46 46 46 46 46 48 49 47 Ionizer DO NOTTOUCH 44 ...
Page 45: ...49 50 48 47 45 ...
Page 47: ...every 6 months see page 44 see page 48 Soaps Neutral household detergents pH7 47 ...
Page 48: ...refer page 47 48 ...
Page 49: ...48 49 ...
Page 51: ...44 46 46 46 47 47 47 48 47 48 45 51 ...
Page 67: ...3 For the embedded piping This can be used for left rear piping left bottom piping also 67 ...
Page 81: ...13 Technical Data 81 ...
Page 82: ...82 ...
Page 96: ...96 ...
Page 98: ...18 1 REMOTE CONTROL 98 ...
Page 99: ...18 2 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD 99 ...
Page 100: ...18 3 PRINT PATTERN OUTDOOR UNIT PRINTED CIRCUIT BOARD VIEW 100 MAICO Printed in Malaysia ...