8.1.18. Ionizer Operation
8.1.17. Indoor Power Relay Control
Power relay will turn on during operation or in progress of stopping operation. Although operation stops, the power relay continues
on for three minutes.
However, during instantaneous power failure (< 0.5s), power relay will turn off. Then, it will turn on 2 minutes after power recover
and the unit will operate as previous operation condition.
Purpose
To provide fresh air effect to users by discharging minus ion to air.
Control Condition
a. Ionizer Only Operation.
1. When air-conditioner unit is at “OFF” condition (standby) and ION operation button at remote control is pressed.
Fan & ionizer on, ION LED illuminates, but power LED maintain off. (1
→
2)
However, fan speed can be adjusted later by customer during this operation.
Airflow direction (Horizontal Vane) control:
Follow vane direction control at cooling mode.
Horizontal vane can be changed by customer during ion only operation.
b. Operation Mode + Ionizer Operation.
1. Ionising Operation Start Condition
When air conditioner unit is in “ON” condition (Heat, Cool, Dry, Fan, Auto mode) and ION operation button at remote control
is pressed. Ionizer on & ION LED illuminates. (3
→
4)
Power LED also illuminates.
2. Ionising Operation Stop Condition
When one of the following condition is satisfied, ION operation stops.
a. Stopped by ON/OFF switch.
b. Timer OFF activates.
c.
ION operation button is pressed again.
d. ION feedback signal shows error.
30
Summary of Contents for CS-E18CKE
Page 10: ...4 Dimensions 10 ...
Page 11: ...11 ...
Page 12: ...5 Refrigeration Cycle Diagram 12 ...
Page 13: ...6 Block Diagram 13 ...
Page 14: ...7 Wiring Diagram 14 ...
Page 20: ...B Indoor Fan Control i Indoor fan control operation outline 1 Cooling Dry 2 Heating 20 ...
Page 44: ...9 Operating Instructions 45 46 45 46 46 46 46 46 48 49 47 Ionizer DO NOTTOUCH 44 ...
Page 45: ...49 50 48 47 45 ...
Page 47: ...every 6 months see page 44 see page 48 Soaps Neutral household detergents pH7 47 ...
Page 48: ...refer page 47 48 ...
Page 49: ...48 49 ...
Page 51: ...44 46 46 46 47 47 47 48 47 48 45 51 ...
Page 67: ...3 For the embedded piping This can be used for left rear piping left bottom piping also 67 ...
Page 81: ...13 Technical Data 81 ...
Page 82: ...82 ...
Page 96: ...96 ...
Page 98: ...18 1 REMOTE CONTROL 98 ...
Page 99: ...18 2 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD 99 ...
Page 100: ...18 3 PRINT PATTERN OUTDOOR UNIT PRINTED CIRCUIT BOARD VIEW 100 MAICO Printed in Malaysia ...