3 Product Specifications
Unit
CS-E18CKE
CU-E18CKE
Cooling Capacity
kW
kcal/h
BTU/h
5.30 (0.90 - 6.00)
4,560 (770 - 5,160)
18,100 (3,070 - 20,500)
Heating Capacity
kW
kcal/h
BTU/h
6.60 (0.90 - 8.00)
5,680 (770 - 6,880)
22,500 (3,070 - 27,300)
Moisture Removal
l/h
Pint/h
2.9
(6.1)
Power Source
Phase
V
Cycle
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Indoor Air (Lo)
m
3
/min (cfm)
Cooling; 12.5 (440)
—
Heating; 13.9 (490)
Indoor Air (Me)
m
3
/min (cfm)
Cooling; 14.0 (490)
—
Heating; 15.5 (540)
Indoor Air (Hi)
m
3
/min (cfm)
Cooling; 15.6 (550)
40.0 (1,410)
Heating; 17.1 (600)
dB (A)
Cooling; High 44, Low 37
Cooling; 47
Heating; High 44, Low 37
Heating; 47
Noise Level
Power level dB
Cooling; High 57
Cooling; High 60
Heating; High 57
Heating; High 60
Electrical Data
Input Power
W
Cooling; 1,650 (240 - 2,050)
Heating; 1,790 (280 - 2,650)
Running Current
A
Cooling; 7.4
Heating; 8.0
EER
W/W
Cooling; 3.21 (3.75 - 2.93)
BTU/hW
Cooling; 11.0 (12.8 - 10.0)
COP
W/W
Heating; 3.69 (3.21 - 3.02)
BTU/hW
Heating; 12.6 (11.0 - 10.3)
Starting Current
A
8.0
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 1/2”
L ; Half Union 1/4”
G ; 3-way valve 1/2”
L ; 2-way valve 1/4”
6
Summary of Contents for CS-E18CKE
Page 10: ...4 Dimensions 10 ...
Page 11: ...11 ...
Page 12: ...5 Refrigeration Cycle Diagram 12 ...
Page 13: ...6 Block Diagram 13 ...
Page 14: ...7 Wiring Diagram 14 ...
Page 20: ...B Indoor Fan Control i Indoor fan control operation outline 1 Cooling Dry 2 Heating 20 ...
Page 44: ...9 Operating Instructions 45 46 45 46 46 46 46 46 48 49 47 Ionizer DO NOTTOUCH 44 ...
Page 45: ...49 50 48 47 45 ...
Page 47: ...every 6 months see page 44 see page 48 Soaps Neutral household detergents pH7 47 ...
Page 48: ...refer page 47 48 ...
Page 49: ...48 49 ...
Page 51: ...44 46 46 46 47 47 47 48 47 48 45 51 ...
Page 67: ...3 For the embedded piping This can be used for left rear piping left bottom piping also 67 ...
Page 81: ...13 Technical Data 81 ...
Page 82: ...82 ...
Page 96: ...96 ...
Page 98: ...18 1 REMOTE CONTROL 98 ...
Page 99: ...18 2 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD 99 ...
Page 100: ...18 3 PRINT PATTERN OUTDOOR UNIT PRINTED CIRCUIT BOARD VIEW 100 MAICO Printed in Malaysia ...