30
4 REMOTE CONTROL RECEIVING SOUND OFF/ON MODE
The Remote Control Receiving Sound OFF/ON Mode will be activated if the Auto OFF/ON button is pressed
continuously for more than 16 seconds (4 “beep” sounds will occur at 16
th
seconds to identify the Remote
Control Receiving Sound OFF/ON Mode is in standby condition) and press “AC Reset” button at remote
control.
Press Auto OFF/ON button to toggle remote control receiving sound.
- Short “beep”:
Turn OFF remote control receiving sound.
- Long “beep”:
Turn ON remote control receiving sound.
After Auto OFF/ON button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON
Mode is restarted.
14.2 Remote
Control
Button
14.2.1 SET
Button
To check remote control transmission code and store the transmission code to EEPROM
o
Press “Set” button continuously for 10 seconds by using pointer
o
Press “Timer Set” button unit a “beep” sound is heard as confirmation of transmission code change.
14.2.2 RESET
(RC)
To clear and restore the remote control setting to factory default.
o
Press once to clear the memory
14.2.3 RESET
(AC)
To restore the unit’s setting to factory default.
o
Press once to restore the unit’s setting
14.2.4 TIMER
▲
To change indoor unit indicator’s LED intensity:
o
Press continuously for 5 seconds.
14.2.5 TIMER
▼
To change remote control display from Degree Celsius (°C) to Degree Fahrenheit (°F)
o
Press continuously for 10 seconds.
14.2.6 CLOCK
Button
To change the remote control time format:
o
Press for more than 5 seconds
Summary of Contents for CS-E12NKUAW
Page 8: ...8 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 9: ...9 5 Dimensions 5 1 Indoor Unit ...
Page 10: ...10 6 Refrigeration Cycle Diagram ...
Page 11: ...11 7 Block Diagram ...
Page 12: ...12 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 13: ...13 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 14: ...14 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 15: ...15 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 34: ...34 15 3 Error Code Table ...
Page 64: ...64 16 1 1 2 To remove discharge grille ...
Page 65: ...65 16 1 1 3 To remove control board 16 1 1 4 To remove cross flow fan and indoor fan motor ...
Page 66: ...66 ...