25
Control
contents
o
Fan speed auto
Indoor FM RPM depends on pipe temperature sensor of indoor heat exchanger. Auto fan speed is
changed from normal setting to quiet setting of respective fan speed. This is to reduce sound of Hi, Me,
Lo for 3dB.
o
Fan speed manual
Manual fan speed for quiet operation is -1 step from setting fan speed.
12.7 Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift lower up to 3.6°F (for Cooling/Soft
Dry) or higher up to 6.3°F (for Heating) than remote control setting temperature for 20 minutes to achieve the
setting temperature quickly.
12.8 Timer
Control
12.8.1 ON
Timer
Control
ON Timer can be set using remote control, where the unit with timer set will start operation earlier than the setting
time. This is to provide a comfortable environment when reaching the set ON time.
60 minutes before the set ON time, indoor (at fan speed of Lo-) and outdoor fan motor start operation for 30
seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the
operation starting time.
From the above judgment, the decided operation will start operation earlier than the set time as shown below.
12.8.2
OFF Timer Control
OFF Timer can be set using remote control, the unit with timer set will stop at set time.
12.9 Auto
Restart
Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
This type of control is not applicable during ON/OFF Timer setting.
This control can be omitted by short the circuit of JP1 (refer P.C.B. indoor circuit).
Summary of Contents for CS-E12NKUAW
Page 8: ...8 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 9: ...9 5 Dimensions 5 1 Indoor Unit ...
Page 10: ...10 6 Refrigeration Cycle Diagram ...
Page 11: ...11 7 Block Diagram ...
Page 12: ...12 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 13: ...13 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 14: ...14 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 15: ...15 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 34: ...34 15 3 Error Code Table ...
Page 64: ...64 16 1 1 2 To remove discharge grille ...
Page 65: ...65 16 1 1 3 To remove control board 16 1 1 4 To remove cross flow fan and indoor fan motor ...
Page 66: ...66 ...