13
Inner Diameter
mm
16
Drain Hose
Length mm
650
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row x Stage x FPI
2 x 15 x 17
Indoor Heat
Exchanger
Size (W x H x L)
mm
810 x 315 x 25.4
Fin Material
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 31 x 19
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
36.4 x 651 x 854.5:824.5
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Contol
Protection Device
Electronic Contol
Dry Bulb
Wet Bulb
Maximum 32
23
Cooling
Minimum 16
11
Maximum 30
-
Indoor
Operation
Range
Heating
Minimum 16
-
Maximum 43
26
Cooling
Minimum 16
11
Maximum 24
18
Outdoor
Operation
Range
Heating
Minimum -5
-6
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5.
Specifications are subjected to change without prior notice for further improvement.
Summary of Contents for CS-E12NKDW
Page 15: ...15 Outdoor Unit U 2E15GBE Outdoor Unit U 2E18CBPG ...
Page 16: ...16 Outdoor Unit U 3E18JBE ...
Page 17: ...17 Outdoor Unit U 4E23JBE ...
Page 18: ...18 ...
Page 20: ...20 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 21: ...21 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E7NK CS E9NK CS E12NK CS E15NK ...
Page 22: ...22 5 1 2 CS E18NK ...
Page 23: ...23 5 2 Outdoor Unit 5 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD 5 2 2 CU E18NKD ...
Page 24: ...24 6 Refrigeration Cycle Diagram 6 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 25: ...25 6 2 CU E18NKD ...
Page 26: ...26 7 Block Diagram 7 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 27: ...27 7 2 CU E18NKD ...
Page 29: ...29 8 1 2 CS E18NKDW ...
Page 30: ...30 8 2 Outdoor Unit 8 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 31: ...31 8 2 2 CU E18NKD ...
Page 33: ...33 9 1 2 CS E18NKDW ...
Page 34: ...34 9 2 Outdoor Unit 9 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 35: ...35 9 2 2 CU E18NKD ...
Page 36: ...36 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 38: ...38 10 1 5 Human Activity Sensor Printed Circuit Board ...
Page 39: ...39 10 2 Outdoor Unit 10 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 40: ...40 10 2 2 CU E18NKD ...
Page 73: ...73 16 3 Error Code Table ...
Page 74: ...74 ...
Page 105: ...105 Figure 3 Figure 4 17 1 1 3 To remove discharge grille Figure 5 ...
Page 107: ...107 Figure 9 Figure 10 ...
Page 109: ...109 Figure 14 Figure 15 17 2 1 4 To remove discharge grille Figure 16 ...
Page 111: ...111 Figure 20 Figure 21 ...