42
11.2 Indoor Unit
11.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to
prevent it from the vibration.
The center of installation plate should be at more than
c
at right and left of the wall.
The distance from installation plate edge to ceiling
should more than
d
.
From installation plate left edge to unit’s left side is
e
.
From installation plate right edge to unit’s right side is
f
.
○
B
: For left side piping, piping connection for
liquid should be about
g
from this line.
: For left side piping, piping connection for gas
should be about
h
from this line.
1 Mount the installation plate on the wall with
5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall,
consider using anchor bolts.)
o
Always mount the installation plate
horizontally by aligning the marking-off
line with the thread and using a level
gauge.
2 Drill the piping plate hole with ø70 mm hole-
core drill.
o
Line according to the left and right side of
the installation plate. The meeting point
of the extended line is the center of the
hole. Another method is by putting
measuring tape at position as shown in
the diagram above. The hole center is
obtained by measuring the distance
namely 128 mm for left and right hole
respectively.
o
Drill the piping hole at either the right or
the left and the hole should be slightly
slanting to the outdoor side.
11.2.2 To Drill a Hole in the Wall and
Install a Sleeve of Piping
1 Insert the piping sleeve to the hole.
2 Fix the bushing to the sleeve.
3 Cut the sleeve until it extrudes about 15 mm
from the wall.
4 Finish by sealing the sleeve with putty or
caulking compound at the final stage.
11.2.3 Indoor Unit Installation
Summary of Contents for CS-E12NKDW
Page 15: ...15 Outdoor Unit U 2E15GBE Outdoor Unit U 2E18CBPG ...
Page 16: ...16 Outdoor Unit U 3E18JBE ...
Page 17: ...17 Outdoor Unit U 4E23JBE ...
Page 18: ...18 ...
Page 20: ...20 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 21: ...21 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E7NK CS E9NK CS E12NK CS E15NK ...
Page 22: ...22 5 1 2 CS E18NK ...
Page 23: ...23 5 2 Outdoor Unit 5 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD 5 2 2 CU E18NKD ...
Page 24: ...24 6 Refrigeration Cycle Diagram 6 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 25: ...25 6 2 CU E18NKD ...
Page 26: ...26 7 Block Diagram 7 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 27: ...27 7 2 CU E18NKD ...
Page 29: ...29 8 1 2 CS E18NKDW ...
Page 30: ...30 8 2 Outdoor Unit 8 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 31: ...31 8 2 2 CU E18NKD ...
Page 33: ...33 9 1 2 CS E18NKDW ...
Page 34: ...34 9 2 Outdoor Unit 9 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 35: ...35 9 2 2 CU E18NKD ...
Page 36: ...36 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 38: ...38 10 1 5 Human Activity Sensor Printed Circuit Board ...
Page 39: ...39 10 2 Outdoor Unit 10 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Page 40: ...40 10 2 2 CU E18NKD ...
Page 73: ...73 16 3 Error Code Table ...
Page 74: ...74 ...
Page 105: ...105 Figure 3 Figure 4 17 1 1 3 To remove discharge grille Figure 5 ...
Page 107: ...107 Figure 9 Figure 10 ...
Page 109: ...109 Figure 14 Figure 15 17 2 1 4 To remove discharge grille Figure 16 ...
Page 111: ...111 Figure 20 Figure 21 ...