61
12.14
E-ion operation
This operation provides clean air by producing negative ions to attract dust captured at the positively charged
active e-ion filters.
e-ion operation start condition
o
During unit running at any operation mode, if “e-ion” operation is selected, combination operation (operation
mode + e-ion operation) starts.
o
During unit is OFF, if “e-ion” operation is selected, e-ion individual operation starts.
e-ion operation stop condition
o
When “OFF/ON” button is pressed to stop the operation.
o
When “PATROL/e-ion” button is pressed.
o
When OFF Timer activates.
e-ion operation pause condition
o
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after
indoor fan restarts.
o
When indoor intake temperature
≥
40°C. e-ion operation resume after indoor intake temperature < 40°C
continuously for 30 minutes.
Indoor
fan
control
o
During any operation mode combines with e-ion operation, fan speed follows respective operation mode.
o
During e-ion individual operation – only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
Speed button is pressed, no signal is sent to air conditioner, and no change on LCD display.
Auto Fan Speed for e-ion operation switches from SHi to Hi after 4 hours of operation.
Airflow direction control
o
During any operation mode combines with e-ion operation, airflow direction follows respective operation
mode.
o
During e-ion individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
signal is sent to air conditioner, and no change on LCD display.
Timer
control
o
When ON timer activates when unit stops, previous operation resumes and restored last saved e-ion
operation status.
o
When ON timer activates during any operation, no change and carry on current operation.
o
When OFF timer activates during any operation, all operation stops and the latest e-ion operation status is
saved.
Indicator
o
When e-ion operation starts, e-ion indicator ON.
Remote Control Receiving Sound
o
Normal
Operation
Î
e-ion Operation
: Beep
o
e-ion
Operation
Î
Normal Operation
: Beep
o
Stop
Î
e-ion individual Operation
: Beep
o
e-ion individual Operation
Î
Stop
:
Long
Beep
Power
failure
o
During e-ion individual operation, if power failure occurs, after power resumes, e-ion individual operation
resumes immediately.
o
During combination operation, if power failure occurs, after power resumes, combination operation resume
immediately.
o
e-ion operation status is not memorized after OFF the unit. After OFF, when the operation is ON again, air
conditioner operates without e-ion operation.
Summary of Contents for CS-C12MKV
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C9MKV CS C12MKV ...
Page 14: ...14 5 1 2 CS C18MKV CS C24MKV CS C28MKV ...
Page 15: ...15 5 2 Outdoor Unit 5 2 1 CU C9MKV 5 2 2 CU C12MKV ...
Page 16: ...16 5 2 3 CU C18MKV CU C24MKV CU C28MKV ...
Page 17: ...17 6 Refrigeration Cycle Diagram ...
Page 18: ...18 7 Block Diagram 7 1 1 CS C9MKV CU C9MKV CS C12MKV CU C12MKV ...
Page 19: ...19 7 1 2 CS C18MKV CU C18MKV CS C24MKV CU C24MKV ...
Page 20: ...20 7 1 3 CS C28MKV CU C28MKV ...
Page 26: ...26 9 Electronic Circuit Diagram 9 1 CS C9MKV CU C9MKV ...
Page 27: ...27 9 2 CS C12MKV CU C12MKV ...
Page 28: ...28 9 3 CS C18MKV CU C18MKV ...
Page 29: ...29 9 4 CS C24MKV CU C24MKV ...
Page 30: ...30 9 5 CS C28MKV CU C28MKV ...
Page 32: ...32 10 1 1 2 CS C18MKV CS C24MKV CS C28MKV ...
Page 34: ...34 10 1 6 Human Activity Sensor Printed Circuit Board ...
Page 77: ...77 Figure 3 Figure 4 16 1 1 3 To remove discharge grille Figure 5 ...
Page 79: ...79 Figure 9 Figure 10 ...
Page 81: ...81 16 2 1 3 To remove power electronic controller Figure 13 Figure 14 Figure1 5 ...
Page 83: ...83 Figure 19 Figure 20 Figure 21 ...
Page 85: ...85 16 3 1 3 To remove power electronic controller Figure 24 Figure 8 Figure 9 ...
Page 87: ...87 Figure 30 Figure 31 Figure 32 ...
Page 88: ...88 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...