66
•
During ECO Patrol operation, the internal setting temperature and fan speed are adjusted in order to provide
comfort and energy saving.
•
ECO Patrol Start condition.
Press ECO Patrol button to select ECO1 and ECO2.
•
ECO Patrol Stop condition.
Press ECO Patrol button again.
OFF Timer activates.
Press OFF/ON button to turn off the air conditioner.
Press AUTO OFF/ON button to turn off the air conditioner.
Press POWERFUL/QUIET button.
Press Mild Dry Cooling button.
•
ECO Patrol operation could ON when any of the following conditions is fulfilled:
During forced cooling or forced heating operation.
During e-ion or individual patrol operation.
•
Power Failure
ECO Patrol operation will be resuming after recovered from power failure.
•
Timer Operation
When unit is turn on by ON Timer and ECO Patrol operation is ON during previous operation before OFF,
ECO Patrol operation will not be ON automatically.
When unit is turn on by ON Timer and ECO Patrol operation is OFF during previous operation before
OFF, ECO Patrol operation will not be ON automatically.
•
Other Information
ECO Patrol, Powerful, Quiet and Mild Dry Cooling cannot be operated at the same time.
ECO Patrol sensor initialized time is 70 seconds from power supplied to ECO Patrol sensor, or 70
seconds from the operation start.
•
ECO 1 Operation
-1
o
C
+2
o
C
High
Low
None
Fan Speed
Set
Temperature
Activity Level
Set Speed
Set Speed
Med Fan
+1tap Up
•
ECO 2 Operation
L.America and etc
-1
o
C
+3
o
C
High
Low
None
Fan Speed
Set
Temperature
Activity Level
Set Speed
Set Speed
Med Fan
+1tap Up
* For first 15 minutes only
Summary of Contents for CS-C12KKV
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C9KKV CS C12KKV ...
Page 14: ...14 5 1 2 CS C18KKV CS C24KKV CS C28KKV ...
Page 15: ...15 5 2 Outdoor Unit 5 2 1 CU C9KKV 5 2 2 CU C12KKV ...
Page 16: ...16 5 2 3 CU C18KKV CU C24KKV CU C28KKV ...
Page 18: ...18 7 Block Diagram 7 1 1 CS C9KKV CU C9KKV CS C12KKV CU C12KKV ...
Page 19: ...19 7 1 2 CS C18KKV CU C18KKV CS C24KKV CU C24KKV ...
Page 20: ...20 7 1 3 CS C28KKV CU C28KKV ...
Page 26: ...26 9 Electronic Circuit Diagram 9 1 CS C9KKV CU C9KKV ...
Page 27: ...27 9 2 CS C12KKV CU C12KKV ...
Page 28: ...28 9 3 CS C18KKV CU C18KKV ...
Page 29: ...29 9 4 CS C24KKV CU C24KKV ...
Page 30: ...30 9 5 CS C28KKV CU C28KKV ...
Page 31: ...31 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 32: ...32 10 1 2 Power Printed Circuit Board 10 1 2 1 CS C9KKV CS C12KKV ...
Page 33: ...33 10 1 2 2 CS C18KKV CS C24KKV CS C28KKV ...
Page 76: ...76 Figure 3 Figure 4 Figure 5 16 1 1 3 To remove discharge grille Figure 6 ...
Page 78: ...78 Figure 10 Figure 11 ...
Page 80: ...80 16 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Page 82: ...82 Figure 21 Figure 22 Figure 23 ...
Page 84: ...84 16 3 1 3 To remove power electronic controller Figure 26 Figure 24 Figure 25 Figure 27 ...