10
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 15.88 (5/8)
Standard length
m (ft)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height different
m (ft)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
30 (0.3)
Piping
Length for Additional Gas
m (ft)
7.5 (24.6)
Inner Diameter
mm
16
Drain Hose
Length mm
650
Fin Material
Pre Coat
Fin Type
Slit Fin
Row x Stage x FPI
2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L)
mm
810 x 315 x 25.4
Fin Material
Blue Coated
Fin Type
Slit Fin
Row x Stage x FPI
2 x 28 x 17
Outdoor Heat
Exchanger
Size (W x H x L)
mm
44 x 711.2 x 787.4:821.4
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Outdoor
Power Supply Cord
A
20
Thermostat
Mechanical
Protection Device
-
Dry Bulb
Wet Bulb
Maximum 32
23
Indoor Operation Range
Minimum 16
11
Maximum 43
26
Outdoor Operation Range
Minimum 16
11
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Specifications are subjected to change without prior notice for further improvement.
Summary of Contents for CS-C12KKV
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C9KKV CS C12KKV ...
Page 14: ...14 5 1 2 CS C18KKV CS C24KKV CS C28KKV ...
Page 15: ...15 5 2 Outdoor Unit 5 2 1 CU C9KKV 5 2 2 CU C12KKV ...
Page 16: ...16 5 2 3 CU C18KKV CU C24KKV CU C28KKV ...
Page 18: ...18 7 Block Diagram 7 1 1 CS C9KKV CU C9KKV CS C12KKV CU C12KKV ...
Page 19: ...19 7 1 2 CS C18KKV CU C18KKV CS C24KKV CU C24KKV ...
Page 20: ...20 7 1 3 CS C28KKV CU C28KKV ...
Page 26: ...26 9 Electronic Circuit Diagram 9 1 CS C9KKV CU C9KKV ...
Page 27: ...27 9 2 CS C12KKV CU C12KKV ...
Page 28: ...28 9 3 CS C18KKV CU C18KKV ...
Page 29: ...29 9 4 CS C24KKV CU C24KKV ...
Page 30: ...30 9 5 CS C28KKV CU C28KKV ...
Page 31: ...31 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 32: ...32 10 1 2 Power Printed Circuit Board 10 1 2 1 CS C9KKV CS C12KKV ...
Page 33: ...33 10 1 2 2 CS C18KKV CS C24KKV CS C28KKV ...
Page 76: ...76 Figure 3 Figure 4 Figure 5 16 1 1 3 To remove discharge grille Figure 6 ...
Page 78: ...78 Figure 10 Figure 11 ...
Page 80: ...80 16 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Page 82: ...82 Figure 21 Figure 22 Figure 23 ...
Page 84: ...84 16 3 1 3 To remove power electronic controller Figure 26 Figure 24 Figure 25 Figure 27 ...