11.3.5 Connect the cable to the Outdoor Unit
a) INDOOR POWER SUPPLY MODEL (1.0 ~
2.5HP)
1 Remove the control board cover from the
unit by loosening the screw.
2
Connecting cable
between indoor unit and
outdoor unit shall be approved
polychloroprene sheathed 3 x 1.5mm
2
(1.0 ~
1.5HP) or 3 x 2.5mm
2
(2.0 ~ 2.5HP) flexible
cord, type designation 245 IEC 57 or heavier
cord. Do not use joint connection cable.
Replace the wire if the existing wire (from
concealed wiring, or otherwise) is too short.
3 Secure the cable onto the control board with
the holder.
4 Attach the control board cover back to the
original position with the screw.
5 For wire stripping and connection requirement,
refer to instruction
g
of the indoor unit.
This equipment must be properly earthed.
•
Earth wire shall be Yellow/Green (Y/G) in colour
and longer than the other AC wires for safety
reason.
b) OUTDOOR POWER SUPPLY MODEL (3.0HP)
1 Remove the control board cover from the unit by loosening the screw.
2 Cable connection to the power supply through Isolating Devices (Disconnecting means).
o
Connect the approved polychloroprene sheathed
power supply cord
3 x 4.0 mm
2
(3.0HP) type
designation 245 IEC 57 or heavier cord to the terminal board, and connect the other end of the cord to
Isolating Devices (Disconnecting means).
o
Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or
otherwise) is too short.
o
In unavoidable case, joining of power supply cord between isolating devices and terminal board of air
conditioner shall be done by using approved socket and plug rated 25A (3.0HP). Wiring work to both
socket and plug must follow to national wiring standard.
3
Connecting cable
between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 x 1.5
mm
2
flexible cord, type designation 245 IEC 57 or heavier cord. Do not use joint connection cable. Replace
the wire if the existing wire (from concealed wiring, or otherwise) is too short.
4 Connect the power supply cord and connecting cable between indoor unit and outdoor unit according to the
diagram below.
5 Secure the power supply cord and connecting cable onto the control board with the holder.
6 Attach the control board cover back to the original position with screw.
Summary of Contents for CS-C12KKV
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C9KKV CS C12KKV ...
Page 14: ...14 5 1 2 CS C18KKV CS C24KKV CS C28KKV ...
Page 15: ...15 5 2 Outdoor Unit 5 2 1 CU C9KKV 5 2 2 CU C12KKV ...
Page 16: ...16 5 2 3 CU C18KKV CU C24KKV CU C28KKV ...
Page 18: ...18 7 Block Diagram 7 1 1 CS C9KKV CU C9KKV CS C12KKV CU C12KKV ...
Page 19: ...19 7 1 2 CS C18KKV CU C18KKV CS C24KKV CU C24KKV ...
Page 20: ...20 7 1 3 CS C28KKV CU C28KKV ...
Page 26: ...26 9 Electronic Circuit Diagram 9 1 CS C9KKV CU C9KKV ...
Page 27: ...27 9 2 CS C12KKV CU C12KKV ...
Page 28: ...28 9 3 CS C18KKV CU C18KKV ...
Page 29: ...29 9 4 CS C24KKV CU C24KKV ...
Page 30: ...30 9 5 CS C28KKV CU C28KKV ...
Page 31: ...31 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 32: ...32 10 1 2 Power Printed Circuit Board 10 1 2 1 CS C9KKV CS C12KKV ...
Page 33: ...33 10 1 2 2 CS C18KKV CS C24KKV CS C28KKV ...
Page 76: ...76 Figure 3 Figure 4 Figure 5 16 1 1 3 To remove discharge grille Figure 6 ...
Page 78: ...78 Figure 10 Figure 11 ...
Page 80: ...80 16 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Page 82: ...82 Figure 21 Figure 22 Figure 23 ...
Page 84: ...84 16 3 1 3 To remove power electronic controller Figure 26 Figure 24 Figure 25 Figure 27 ...