1.
Confirm that both the 2-way and 3-way valves are set to
the opened position.
•
Remove the valve stem caps and confirm that the valve
stems are in the opened position.
•
Be sure to use a hexagonal wrench to operate the valve
stems.
2.
Operate the unit for 10 to 15 minutes.
3.
Stop operation and wait for 3 minutes, then connect the
charge set to the service port of the 3-way valve.
•
Connect the charge hose with the push pin to the Gas
service port.
4.
Air purging of the charge hose.
•
Open the low-pressure valve on the charge set slightly
to purge air from the charge hose.
5.
Set the 2-way valve to the close position.
6.
Operate the air conditioner at the cooling cycle and
stop it when the gauge indicates 1 kg/cm
2
G (0.1 MPa).
7.
Immediately set the 3-way valve to the closed position.
•
Do this quickly so that the gauge ends up indicating 3 to
5 kg/cm
2
G (0.3 to 0.5 MPa).
8.
Disconnect the charge set, and mount the 2-way and 3-
way valve’s stem nuts and the service port caps.
•
Use a torque wrench to tighten the service port cap to a
torque of 1.8 kg.m (18 N.m).
•
Be sure to check for gas leakage.
11.2.2. Pumping down (Re-installation)
Procedure:
59
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
Summary of Contents for CS-A18DKD
Page 11: ...4 2 Outdoor Unit 4 2 1 CU A18DKD CU A24DKD 11 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 13: ...6 Block Diagram 13 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 14: ...7 Wiring Diagram CS A18DKD CU A18DKD CS A24DKD CU A24DKD 14 ...
Page 35: ...9 Operating Instructions 35 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 36: ...36 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 37: ...37 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 38: ...38 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 39: ...39 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 40: ...40 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 45: ...3 For the embedded piping 45 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 70: ...14 Technical Data 14 1 Thermostat characteristics 70 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 71: ...14 2 Operation characteristics 71 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 72: ...72 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 81: ...81 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 83: ...19 2 Remote Control 83 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...