(After Evacuation)
Procedure:
1.
Connect the charge hose to the charging cylinder.
•
Connect the charge hose which you disconnected from
the vacuum pump to the valve at the bottom of the
cylinder.
2.
Purge the air from the charge hose.
•
Open the valve at the bottom of the cylinder and press
the check valve on the charge set to purge the air (be
careful of the liquid refrigerant).
3.
Open the valve (Low side) on the charge set and charge
the system with liquid refrigerant.
•
If the system cannot be charged with the specified
amount of refrigerant, it can be charged with a little at a
time (approximately 150 g each time) while operating
the air conditioner in the cooling cycle; however, one
time is not sufficient, wait approximately 1 minute and
then repeat the procedure. (pumping down-pin)
This is different from previous procedures. Because you are
charging with liquid refrigerant from the gas side, absolutely do
no attempt to charge with large amount of liquid refrigerant
while operating the air conditioner.
4.
Immediately disconnect the charge hose from the 3-
way valve’s service port.
•
Stopping partway will allow the refrigerant to be
discharged.
•
If the system has been charged with liquid refrigerant
while operating the air conditioner, turn off the air
conditioner before disconnecting the hose.
5.
Mount the valve stem caps and the service port cap.
•
Use torque wrench to tighten the service port cap to a
torque of 18 N.m.
•
Be sure to check for gas leakage.
11.1.6. Gas charging
57
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
Summary of Contents for CS-A18DKD
Page 11: ...4 2 Outdoor Unit 4 2 1 CU A18DKD CU A24DKD 11 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 13: ...6 Block Diagram 13 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 14: ...7 Wiring Diagram CS A18DKD CU A18DKD CS A24DKD CU A24DKD 14 ...
Page 35: ...9 Operating Instructions 35 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 36: ...36 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 37: ...37 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 38: ...38 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 39: ...39 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 40: ...40 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 45: ...3 For the embedded piping 45 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 70: ...14 Technical Data 14 1 Thermostat characteristics 70 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 71: ...14 2 Operation characteristics 71 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 72: ...72 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 81: ...81 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 83: ...19 2 Remote Control 83 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...