8.5.7. Anti-Dew Formation Control
•
Purpose is to prevent dew formation on indoor unit air discharge area.
•
When room temperature is constant (±1°C) the following conditions occur for 30 minutes continuously, anti-dew formation will
activate:
−
Remote Control setting temperature is less than 25°C.
−
Compressor is on.
−
Cooling operation mode.
−
Indoor Fan motor operate at Low fan speed or QLo.
•
This control is cancelled immediately when above condition is changed.
•
Anti-Dew formation is control by:
1. Increasing Air Flow Volume
a. Lo fan speed
Lo fan speed is changed to Lo+ after 30 min to prevent dew formation.
b. QLo fan speed
Dew formation may occurs at QLo cool, therefore QLo cool is operated only 1 hr 30 min (1 hr QLo, 30 min QLo +100
rpm). After that, it operates at QLo +180rpm (However Quiet LED remains on).
2. Norrowing
Vertical Airflow Direction
−
During Anti-dew condensation prevention, Airflow Direction Auto-control angle change from 10° - 38° to 10° - 27° under
Cooling and Soft Dry operation mode.
21
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
Summary of Contents for CS-A18DKD
Page 11: ...4 2 Outdoor Unit 4 2 1 CU A18DKD CU A24DKD 11 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 13: ...6 Block Diagram 13 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 14: ...7 Wiring Diagram CS A18DKD CU A18DKD CS A24DKD CU A24DKD 14 ...
Page 35: ...9 Operating Instructions 35 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 36: ...36 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 37: ...37 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 38: ...38 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 39: ...39 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 40: ...40 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 45: ...3 For the embedded piping 45 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 70: ...14 Technical Data 14 1 Thermostat characteristics 70 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 71: ...14 2 Operation characteristics 71 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 72: ...72 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 81: ...81 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 83: ...19 2 Remote Control 83 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...