2.2. Indoor Unit
Ionizer Operation
• Generate and discharge negative ion.
Random Auto Restart Control
• Unit will be restarted, when resume from
power failure, at previous setting.
Anti-Freezing Control
• To prevent indoor heat exchanger from
freezing.
Indoor Fan Speed Control
• Manual control fan speed
(High, Medium and Low).
• Automatic fan speed
•
•
Vertical airflow control can be adjusted
automatically or manually by remote control.
Horizontal airflow control can be adjusted
automatically or manually by remote control.
Airflow Direction Control
Automatic Operation Button
• Press for < 5 second to operate Automatic
operation mode.Use when the remote
control cannot be used.
• Press for > 5 second to operate Cooling
operation mode and compressor force
to on (“beep” sound will be heard). Used
when test running or servicing.
• Within 20 second of Cooling operation,
press continuously for > 5 second to enter
various setting mode. “beep, beep” sound
will be heard. (Used to toggle remote
control signal receiving sound or select
remote control transmission code.)
AUTO
OFF / ON
Operation Indication Lamps (LED)
•
POWER
(Green) ........ Lights up in operation,
blinks in Automatic
Operation judging.
•
QUIET
(Orange) ........ Lights up in Quiet
Operation.
•
TIMER
(Orange) ....... Lights up in Timer
Setting.
•
POWERFUL
(Orange) .. Lights up in Powerful
Operation.
•
ION
(Green) ........... Lights up in Ionizer
Operation.
•
SUPER
ALLERU-BUSTER
(Blue) ... Lights up in operation.
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Operation.
Powerful Operation
• Reaches the desired room temperature
quickly.
Timer Operation
• Delay OFF/ON Timer control.
Time Delay Safety Control
• Restarting is inhibited for approximately
3 minutes.
Quiet Operation
• To provide quiet operation.
7 Minutes Time Save Control
• To reduce the built up humidity inside
the room.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor
unit discharge area.
Hot-Start Control
• To prevent cold air being discharge during
Heating operation starts.
Anti Cold Draft Control
• To prevent the cold draft during Heating
mode operation in thermo off condition.
4
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD
Summary of Contents for CS-A18DKD
Page 11: ...4 2 Outdoor Unit 4 2 1 CU A18DKD CU A24DKD 11 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 13: ...6 Block Diagram 13 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 14: ...7 Wiring Diagram CS A18DKD CU A18DKD CS A24DKD CU A24DKD 14 ...
Page 35: ...9 Operating Instructions 35 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 36: ...36 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 37: ...37 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 38: ...38 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 39: ...39 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 40: ...40 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 45: ...3 For the embedded piping 45 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 70: ...14 Technical Data 14 1 Thermostat characteristics 70 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 71: ...14 2 Operation characteristics 71 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 72: ...72 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 81: ...81 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...
Page 83: ...19 2 Remote Control 83 CS A18DKD CU A18DKD CS A24DKD CU A24DKD ...