BRIGHTNESS ADJUSTMENTS (HDTV)
Measuring Instruments
Signal generator (Component gray scale signal)
Card (Slot)
Component/RGB Input Card (Slot 1)
Test Points
Adjustment Points
S*02 (Overscan Bright High), S*06 (Overscan Bright Low),
SM** (Underscan Bright High/Low)
[Service Menu]
Notes: • Perform the following adjustments after completing the Contrast and White Balance adjustments.
• Set the SUB PICTURE ADJ. data in the Setup Menu to “00”.
• The value adjusted at the SO adjustment becomes the reference value for the following adjustments. When this data is changed,
it is required to re-adjust the data of all of the adjustment signals (HDTV, SDTV and NTSC/PAL). When re-adjusting the 1080/60i
signal, use the SI.
• When overscan data of a signal is changed, it is required to re-adjust the underscan data of the same adjustment signal.
• After completing the brightness adjustments, make sure that the Low-Light is not deviated. If it is, it is required to perform the
Low-Light adjustment again.
— Standard value (SO) adjustment —
<White Balance HIGH: D9300>
1. Apply the 1080/60i component gray scale signal to INPUT A.
2. Set COLOR TEMP. of “COLOR TEMP./BAL.” in the Setup Menu to HIGH.
3. Set the PHASE, CHROMA, BRIGHT and CONTRAST potentiometers on the
front panel to the center click positions.
4. Adjust SO02 in the Service Menu so that the 0% black area in the gray scale
signal lights up slightly. (Be sure to avoid degradation of the black color.)
<White Balance LOW (D65)>
5. Set COLOR TEMP. of “COLOR TEMP./BAL.” in the Setup Menu to LOW.
6. Adjust SO06 so that the 0% black area in the gray scale signal lights slightly.
(Be sure to avoid degradation of the black color.)
— Other signals adjustments —
<White Balance HIGH (D9300)>
7. Apply the 1080/60i component gray scale signal to INPUT A.
8. Set COLOR TEMP. of “COLOR TEMP./BAL.” in the Setup Menu to HIGH.
9. Set the PHASE, CHROMA, BRIGHT and CONTRAST potentiometers on the front panel to the center click positions.
10. Adjust SI02 in the Service Menu so that the 0% black area in the gray scale signal lights up slightly.
(Be sure to avoid degradation of the black color.)
11. Set the UNDER SCAN button on the front panel to ON so that the scanning size is underscanning.
12. Adjust SM26 so that the 0% black area in the gray scale signal lights slightly. (Be sure to avoid degradation of the black color.)
13. Set the UNDER SCAN button on the front panel to OFF.
<White Balance LOW (D65)>
14. Set COLOR TEMP. of “COLOR TEMP./BAL.” in the Setup Menu to LOW.
15. Adjust SI06 so that the 0% black area in the gray scale signal lights slightly. (Be sure to avoid degradation of the black color.)
16. Set the UNDER SCAN button on the front panel to ON so that the scanning size is underscanning.
17. Adjust SM27 so that the 0% black area in the gray scale signal lights slightly. (Be sure to avoid degradation of the black color.)
18. Set the UNDER SCAN button on the front panel to OFF.
19. Vary the adjustment signal and adjustment data, and re-perform adjustments in steps 7 to 18 above (see Table 21).
SIGNAL BRIGHTNESS ADJUSTMENTS
Table 21
0% Black area
0
%
2 4 6 8 10 1214 0
%
2 4 6 8 10 1214
%