44
FRONT ROTATION ADJUSTMENT
Notes: • Perform the following adjustments after completing the
Screen Voltage, High-Voltage, Focusing and X-Ray Pro-
tector adjustments.
• Ensure that CN0RD and CN00R on the S. Correction PWB
are connected to the Deflection Yoke and Main PWB.
• If the S. Correction PWB has VR503 on it, adjust the im-
age tilting by turning VR503 instead of using the remote
control cord (DY01).
1. Apply the 1080/60i size adjustment signal to INPUT A (Terminal Y
on the Component/RGB Input Card).
2. Adjust DY01 of the Service Menu to decrease the image tilting to no
more than 2 mm. If the reference point which is the vertical center
position on the left of the image (reference points) is deviated, ad-
just DM04 to correct it.
FRONT ROTATION ADJUSTMENT
Escutcheon
≤
2 mm
Screen size
Reference
point
S. CORRECTION PWB
MAIN PWB
Front side
Front side
(Top surface view of S. CORRECTION PWB)
TP-XR
TP-G
VR503 [ROTATION]
VR505 [CONV_V]
VR504 [CONV_H]
VR502 [H.VOLTAGE]
VR501 [X-RAY]
CN0RD
CN00R
VR503
VR505
VR504
VR502
VR501
CN0RD
CN00R
Measuring Instruments
Signal generator (Size adjustment signal)
Card (Slot)
Component/RGB Input Card (Slot 1)
Test Points
Adjustment Points
DY01 (Rotation), DM04 (Vertical Position) [Service Menu]
VR503 (ROTATION) [S. CORRECTION PWB]