13
3. ON-SCREEN DISPLAY (SELF DIAGNOSIS DISPLAY MODE)
s
How to enter the self diagnosis display mode:
Press a key on the front panel to display the service menu and select “DIAG-
NOSIS”.
(See “Basic Operations of Service Menu” on page 18.)
s
How to clear the trouble history in the self diagnosis mode:
In the DIAGNOSIS MENU as shown on the left, select “CLEAR”.
A new screen appears. Press the VOL + (
) on the front panel to select
“YES”.
This clears the trouble history in the self diagnosis mode and the symbols dis-
played to the right of all of the items become “
R
”.
s
Trouble history
The trouble history of each item is counted up to 9. The figure is held in the
memory until the trouble history is cleared.
As a result, the displayed trouble history count remains 9 even if it actually
exceeds 9.
CLEAR
I2C-0 SIGNAL BUS
×
9
I2C-1 SIGNAL BUS
I2C ROM BUS
X-RAY
OCP
VOFF
< DIAGNOSIS MENU >
EXIT : MENU
EXIT :
+
Items
: Normal
: Abnormal
SELF DIAGNOSIS DISPLAY MODE
(SERVICE MENU ITEM DIAGNOSIS)
Summary of Contents for BT-H1700P
Page 5: ......