54
55
REMOTE Specifications
(Continued)
Priority of assigned items
•
When [GAMMA SEL. 2.20], [GAMMA SEL. 2.40], [GAMMA SEL. 2.60], [GAMMA SEL. FILM], and [GAMMA SEL. MANUAL SET]
are [ON] at the same time, [GAMMA SEL. 2.20] takes priority. The mode priority order is [GAMMA SEL. 2.20] > [GAMMA SEL.
2.40] > [GAMMA SEL. 2.60] > [GAMMA SEL. FILM] > [GAMMA SEL. MANUAL SET]. The gamma is 2.35 when none of the
GAMMA SEL items is selected.
RS-232C Input Connector
The unit can be operated externally via the RS-232C interface.
For details on the pin arrangement and connection of the RS-232C input connector, refer to the diagram below and the tables on the
right below.
For details on specific systems using RS-232C input connectors, contact your supplier.
RS-232C input connector
(9 pins)
External device side
(Straight)
Device side
Pin
number
Signal
Pin
number
Signal
1
N.C.
1
N.C.
2
RXD
2
TXD
3
TXD
3
RXD
4
DTR
4
DSR
5
GND
5
GND
6
DSR
6
DTR
7
RTS
7
CTS
8
CTS
8
RTS
9
N.C.
9
N.C.
Connectors and signals
Connector: D-SUB 9-pin (female)
Signal
Pin
number
Signal
Description
1
N.C.
Not connected
2
TXD
Transmission data
3
RXD
Reception data
4
DSR
Connected inside
5
GND
Ground
6
DTR
Connected inside
7
CTS
Connected inside
8
RTS
Connected inside
9
N.C.
Not connected
Communication parameters
Signal level
RS-232C compliant
Synchronous system Asynchronous system
Transfer rate
9 600 bps
Parity
None
Data length
8 bit
Stop bit
1 bit
Flow control
None
Command format
STX (02h)
Command : Data
ETX (03h)
•
The command is a 3-character string starting with STX and
ending with ETX.
•
Append any data after the colon (:) following the command, as
required.
Response formats
1.
Setting command response
STX (02h)
Command
ETX (03h)
2.
Query command response
STX (02h)
Data
ETX (03h)
3.
Error response
STX (02h)
Error codes
ETX (03h)
Error codes
ER001: Invalid command
ER002: Parameter error