Function
Iris recognition time:
Approx. 0.3 seconds (After iris image capturing until the recognition result is output)
*
2
Approx. 5 seconds (Server certification. After iris image capturing until the recogni-
tion result is output) *
3
Eye image capturing range:
Approx. 30 cm to 40 cm {0.98 ft. to 1.32 ft.} between the eyes and the mirror
Total number of users enrolled
Stand-alone mode:
50 users max.
Network mode:
5 025 users max.*
4
Iris server:
10 025 users max.*
4
Voice guidance:
14 languages supported (Japanese, English, German, French, Spanish, Italian,
Russian, Chinese, Korean, Portuguese, Turkish, Arabic, Dutch, and Swedish)
Mute, Simple (Recognition result), and Full (Voice guidance, and recognition result)
selectable
Distance indicator:
Five lamps
Live indicator:
Blinking, On, and Off selectable
Angular field view
(video surveillance camera):
Horizontal: 115 °, Vertical: 85° (Fixed)
(In some cases, horizontal angular field of view of option camera is partly missing.)
Security function:
Tamper detection switch, iris data encryption
Time adjustment:
Synchronization with an external master clock
*
1
The third-party external power supply should meet the following specifications, and must be powered by a UL Listed
access control power-limited power supply, capable of 4-hours of standby power.
Rated ripple voltage/Ripple noise:
150 mV[P-P] or less
Overcurrent protection:
Enabled (mandatory)
*
2
This iris reader supports auto negotiation. If you use a hub supporting auto sensing, connection may not be established
due to auto sensing malfunction.
*
3
The recognition time may differ depending on capturing conditions, network conditions, or the total number of enrolled
users.
*
4
User Licence Software BM-EU30000E Series (option) is required.
*
5
Refer to the dealer for available external devices.
*
6
For RS-485 communication, our exclusive protocol is employed.
*
7
For use with RS485 only. Refer to UL Listed Access Control Panels Installation Instructions for compatibility with this UL
Listed reader.
Operating Instructions (This document) .......................... 1 pc.
The following parts are used during installation procedures.
Earth ground cable .......................................................... 1 pc.
Clamping tool ................................................................... 1 pc.
Clamping tool screw (3 mm tapping screw) .................... 1 pc.
Tamperproof screw driver tool ......................................... 1 pc.
Ferrite core ....................................................................... 2 pcs.
Warranty card ................................................................... 1 pc.
Standard Accessories
12 V DC
12 V DC ±0.5 V
Minimum 1.2 A
24 V DC
24 V DC ±0.5 V
Minimum 0.6 A
Output voltage
Output current capacity