Pin No.
Pin No.
22
SW1-1
SW1-2
OFF
RS-485 termination
(card reader)
Selects whether to
activate the termina-
tion of the RS-485
connection with the
card reader.
RS-485 ter-
mination
ON
RS-485 ter-
mination
OFF or
Wiegand
Available only when SW2-3
and SW2-4 are OFF (RS-
485 is selected). When
selecting Wiegand, surely
set this switch to OFF.
Otherwise, communication
may not be established.
Factory
default
OFF
RS-485 termination
(access control
panel)
Selects whether to
activate the termina-
tion of the RS-485
connection with the
access control panel.
RS-485 ter-
mination
ON
RS-485 ter-
mination
OFF or
Wiegand
Available only when SW2-1
and SW2-2 are OFF (RS-
485 is selected). When
selecting Wiegand, surely
set this switch to OFF.
Otherwise, communication
may not be established.
Setting name
Function
ON
OFF
Remarks
SW1-3
SW1-4
OFF
Not used
_
Do not set.
Factory
default
_
OFF
Not used
_
Do not set.
Factory
default
_
SW2-1
SW2-2
OFF
Communication I/F 2
(access control
panel)
Wiegand
RS-485
Factory
default
OFF
Communication I/F 1
(access control
panel)
Selects the interface
for connection with
access control panel.
Determines the func-
tions of
w
-7 to
w
-10.
Wiegand
RS-485
Surely set SW2-1 and
SW2-2 to the same posi-
tion. If the setting is mixed,
communication may not be
established.
Setting name
Function
ON
OFF
Remarks
SW2-3
SW2-4
OFF
Communication I/F 4
(card reader)
Wiegand
RS-485
OFF
Communication I/F 3
(card reader)
Selects the interface
for connection with
card reader.
Determines the func-
tions of
w
-1 to
w
-4.
Wiegand
RS-485
Surely set SW2-3 SW2-4 to
the same position. If the
setting is mixed, communi-
cation may not be estab-
lished.
●
Setup Switches of Interface Board SW2