Roll Unit AW-RL400
44 (E)
ENGLISH
Specifications
Pan/tilt head connector:
Connected to pan/tilt head using cable supplied
Performance:
Maximum load-bearing capability: 4 kg
Rotary range: 380 degrees (approx. ±190 degrees)
Maximum operating speed: 60 degrees/sec.
Repeatability: Less than ±1 degree
Noise level: Less than ???
Ambient operating temperature: 0°C to +40°C
Storage temperature:
–20°C to +60°C
Ambient operating humidity:
30% to 90% (no condensation)
Dimensions (W
!
H
!
D):
205
!
198
!
260 mm
Weight:
Approx. 3.9 kg
Finish:
AV ivory paint (colour resembling Munsell 7.9Y6.8/0.8)
Supply voltage:
DC 24V
Power consumption: Approx. 24W