53
4. Input/output signal settings
[10.3] Input Menu/SDI-IN3
10.
UC:Mvdet/Sharp
[10.4] Input Menu/SDI-IN4
10.
UC:Mvdet/Sharp
Mvdet:
This is used to set the motion detection sensitivity of
the image.
1
((
2
((
3
((
4
((
5
Toward still images
Standard
Toward moving images
Sharp:
This is used to enhance the sharpness of the image
edges.
1
((
2
((
3
((
4
((
5
Not sharp edges
Standard
Very sharp edges
4-1-8. Setting the input image scaling
[10.5] Input Menu/DVI-IN
4.
Scale
This is used to set the scaling for the DVI-D input signal
images.
Listed below are the resolutions of the images which can be
input.
Black images will be displayed if images with other
resolutions or other frequencies are input.
Resolutions supported
XGA
1024
C
768/60 Hz
WXGA
1280
C
768/60 Hz
SXGA
1280
C
1024/60 Hz
WSXGA+
1680
C
1050/60 Hz
UXGA
1600
C
1200/60 Hz
WUXGA
1920
C
1200/60 Hz
1080/59.94p
1920
C
1080/59.94 Hz
1080/50p
1920
C
1080/50 Hz
Select the scaling method from among the options listed
below.
Fit-V
The aspect ratio of the input image is
maintained, and the size of the image is
enlarged or reduced in accordance with the
vertical resolution.
Fit-H
The aspect ratio of the input image is
maintained, and the size of the image is
enlarged or reduced in accordance with the
horizontal resolution.
FULL
The size of the image is enlarged or reduced in
accordance with the system resolution.
p
The aspect ratio of the image is not
maintained.
p
The enlargement and reduction ratios
differ between the horizontal and vertical
directions.
p
For details on which sizes are supported for which
formats, refer to “Table of DVI input scaling sizes” on
the next page.
Summary of Contents for AW-HS50N
Page 74: ...74 8 Connections with a computer Transferring the setup data to the unit 未 ...
Page 75: ...75 8 Connections with a computer Transferring the setup data from the unit 未 ...
Page 91: ...F0410Y0 D Panasonic System Networks Co Ltd 2010 ...
Page 125: ...F0610Y1070 D Panasonic System Networks Co Ltd 2010 ...