101
6. External interfaces
This unit comes with RS-4, GPI and tally connectors to serve as external interfaces.
6-1. RS-422 connector
This enables the unit to be controlled by an external device.
Use it with the settings below. (D-sub 9-pin, female, inch screw)
Baud rate: 38400 bps
Parity:
ODD
Stop bit:
1 bit
1
2
3
4
5
9
8
7
6
Pin assignment
Pin No.
Signal name
Description of signal
1
FRAME GROUND
Frame ground
TXD –
Send data (–)
3
RXD +
Receive data (+)
4
GROUND
Ground
NC
Not used
6
GROUND
Ground
7
TXD +
Send data (+)
8
RXD –
Receive data (–)
9
FRAME GROUND
Frame ground
The following lists the functions which can be controlled by editing controller AG-A80.
(Compliant with the GVG protocol)
• Crosspoint switch
• Wipe pattern selection (BKGD)
• Transition mode (MIX/WIPE) selection
• Auto transition time setting
• Auto transition execution
<Table of wipe patterns supported>
GVG protocol
AV-HS400AE
GVG protocol
AV-HS400AE
GVG protocol
AV-HS400AE
GVG protocol
AV-HS400AE
A
B
A
B
A
B
A
B
0
1
WIPE #1
1
13
SQ #1
4
SL #1
36
37
3D #1
1
WIPE #
13
14
SQ #
6
SL #
37
38
3D #
3
WIPE #3
14
1
SQ #3
6
7
SL #3
38
39
3D #3
3
4
WIPE #4
1
16
SQ #4
7
8
SL #4
39
40
3D #4
4
WIPE #
16
17
SQ #
8
9
SL #
40
41
3D #
6
WIPE #6
17
18
SQ #6
9
30
SL #6
41
4
3D #6
6
7
WIPE #7
18
19
SQ #7
30
31
SL #7
4
43
3D #7
7
8
WIPE #8
19
0
SQ #8
31
3
SL #8
43
44
3D #8
8
9
WIPE #9
0
1
SQ #9
3
33
SL #9
44
4
3D #9
9
10
WIPE #10
1
SQ #10
33
34
—
4
46
3D #10
10
11
WIPE #11
3
—
34
3
—
46
47
3D #11
11
1
WIPE #1
3
4
SQ #1
3
36
—
47
48
3D #1
: Set “No. 6” when control is to be exercised from the AG-A80.
On the System sub menu of the SYSTEM menu, set On or Off for control from the external device (editor)
connected to the RS-4 connector.
For details on the settings, see -6-.