88
Setup Menu: Menu List
Note:
When other than “NORMAL” is selected in the “REC/PB FUNCTION” - “RECORDING” (
➝
page 86) setting menu item, proxy recording
cannot be performed even if “REC MEDIA” is set to “P2” or “P2&SD.”
_ is the factory default setting.
_ is the factory default setting.
PROXY SETUP
Item
Settings and brief function description
FREQ indications
REC MEDIA
Selects the media for proxy data recording.
P2
: Records proxy data to P2 cards.
P2&SD:
Records proxy data to both P2 cards and SD memory cards.
OFF:
Does not record proxy data.
REC MODE (HD)
Sets the recording mode for proxy data. (Only in HD mode)
For details on each mode, refer to “Recording modes and recording signals (video and au-
dio)” (
➝
page 29).
TC SUPER
Sets superimposing the time code display on the proxy data recording video.
UPPER:
Superimposes the time code display at the top of the recording video.
LOWER:
Superimposes the time code display at the bottom of the recording video.
OFF:
Does not superimpose the time code display on the recording video.
TC/UB/CTL
Item
Settings and brief function description
FREQ indications
CTL DISPLAY
Selects the 12- or 24-hour format for the CTL counter display.
±12h:
12-hour format display
24h
: 24-hour format display
TCG MODE
Sets the operating mode of the internal time code generator.
REGEN:
Synchronizes the internal time code generator to maintain continuity with the last time code
recorded on the P2 card.
PRESET:
Starts recording from the value set with the [TC PRESET] button.
EXT:
Uses the external time code input from the TIME CODE IN connector or VITC or SLTC of the
video signal. Set the selection in the “EXT TC SEL” (
➝
page 89) menu item.
UBG MODE
Sets the operating mode for the user bits of the internal time code generator.
REGEN:
Synchronizes the internal time code generator with the last user bit recorded on a P2 card.
PRESET:
Starts recording from the value set with the [TC PRESET] button.
EXT:
Uses the external UB input from the TIME CODE IN connector or VITC or SLTC of the video
signal. Set the selection in the “EXT TC SEL” (
➝
page 89) menu item.
RUN MODE
Sets the operating mode for advancing the internal time code generator.
REC RUN:
Advances the internal time code generator only during recording.
FREE RUN
: Advances the internal time code generator while the power is on regardless of
the operating mode.
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz
59.94Hz
50Hz