112
For Long and Trouble-Free Operation: Warning System
CANNOT PLAY
Displayed when playback was interrupted due to a clip error or other factor.
[Cause]
• Playback was attempted when there were no clips.
• Playback was attempted for a card that cannot be used.
• Other causes that prevent playback or stop playback.
• Playback was attempted when the unit was BUSY.
STOP
DC PWR NEAR END
The voltage of the external DC power supply is low.
Replace the external DC power supply.
Operation
continues
SLOT SEL INVALID
Displayed if the SLOT SEL button (when assigned to a USER button) is
pressed when it is not possible to switch the P2 card recording slot.
Operation
continues
BUSY
Displayed while the clip information is being read or when the clip configura-
tion has changed. No operations can be performed while BUSY is on the
screen.
[Cause]
• A card has been inserted or removed.
• Updating is in progress
• Recording post processing is in progress
• Other causes
Operation
continues
FAN STOPPED
Displayed when the fan motor is stopped.
Operation
continues
BACKUP BATT EMPTY
Displayed when a drop in the backup battery voltage for the internal clock
is detected at power-on.
Ask your dealer to replace the battery.
Operation
continues
REC WARNING
<FRAME SIGNAL>
Displayed when a video or audio error occurs during recording.
To continue operation, turn the power off and then back on.
If the input signal becomes disrupted during recording, recording will
continue but disrupted video will be recorded. Check the signal input to
the unit.
Even if recording is continued, video and sound will be recorded correctly
when the signal returns to normal.
Continues
TEMPORARY PAUSE
IRREGULAR SIG
Displayed when a video or audio error occurs during recording, and re-
cording is paused.
Recording will be resumed automatically when the signal returns to normal.
The clip will be divided. The time code may become non-continuous.
When recording in AVC-G format, remove and reinsert the card after re-
cording is complete, and repair the clips for which “
” (yellow) is dis-
played.
Recording
pauses
REC WARNING
<PULL DOWN>
(When occurs during recording)
REC WARNING
PULL DOWN ERROR
(When occurs not during recording)
The video pull-down sequence and TC values are not synchronized.
Check the signal.
Continues
REC WARNING
<OVER MAX# CLIPS>
Displayed when an attempt was made to record a clip that would result in
the upper limit for the total number of clips being exceeded on one P2
card.
Replace the P2 card or delete unnecessary clips.
STOP
Displayed message
Description
Deck operation