4.1 Installation of the GM1 Series
4.1.1 Installation Environment and Space
■
Installation environment
Use the unit within the range of the general specifications when installing.
● Ambient temperature: 0 to +55°C
● Ambient humidity: 10 to 95% RH (at 25°C, non-condensing)
● Pollution degree: 2
● Altitude: 2,000 m above sea level or lower
● Overvoltage category: II or less
● Installation place: It is assumed to be used in an environment inside a control panel (metal
panel with sufficient strength) that provides a protection rating of IP54 or higher.
Do not use it in the following environments.
● Direct sunlight
● Sudden temperature changes causing condensation.
● Inflammable or corrosive gas.
● Excessive airborne dust, metal particles or saline matter.
● Benzine, paint thinner, alcohol or other organic solvents or strong alkaline solutions such as
ammonia or caustic soda.
● Direct vibration, shock or direct drop of water.
● Influence from power transmission lines, high voltage equipment, power cables, power
equipment, radio transmitters, or any other equipment that would generate high switching
surges. (100 mm or more)
■
Handling instructions
● Do not directly touch connector pins directly to prevent electrostatic discharge failure.
● Always rid yourself of any static electricity before handling this product.
● Do not connect a unit other than our GM1 series to the side connector on the unit.
● Use copper wires with a temperature rating of 80°C.
■
Measures regarding heat radiation
● As countermeasures against heat radiation, install the unit in the direction shown below.
● Do not install the unit stacked up, horizontally or upside down. Doing so will prevent proper
cooling of the unit and cause overheating inside.
4.1 Installation of the GM1 Series
4-2
WUME-GM1H-02
Summary of Contents for AGM1CSEC16P
Page 1: ...Motion Controller GM1 Series Reference Manual Hardware WUME GM1H 02 2021 8 ...
Page 2: ... MEMO 2 WUME GM1H 02 ...
Page 4: ... MEMO iv WUME GM1H 02 ...
Page 8: ... MEMO viii WUME GM1H 02 ...
Page 12: ... MEMO 1 4 WUME GM1H 02 ...
Page 39: ...3 2 Expansion Units WUME GM1H 02 3 19 ...
Page 40: ... MEMO 3 20 WUME GM1H 02 ...
Page 70: ... MEMO 6 6 WUME GM1H 02 ...
Page 75: ...8 Device Reset 8 1 Device Reset by GM1 Controller Operation 8 2 WUME GM1H 02 8 1 ...
Page 84: ... MEMO 9 8 WUME GM1H 02 ...
Page 85: ...10 Maintenance and Inspection 10 1 Inspection 10 2 WUME GM1H 02 10 1 ...
Page 117: ...Pulse Output Unit Unit mm 11 6 Dimensions WUME GM1H 02 11 31 ...
Page 118: ... MEMO 11 32 WUME GM1H 02 ...
Page 122: ... MEMO App 4 WUME GM1H 02 ...
Page 124: ... MEMO WUME GM1H 02 ...
Page 125: ... MEMO WUME GM1H 02 ...
Page 126: ...Panasonic Corporation 2021 August 2021 WUME GM1H 02 ...