![Panasonic AG-HMC150P/AN Service Information Download Page 43](http://html.mh-extra.com/html/panasonic/ag-hmc150p-an/ag-hmc150p-an_service-information_258894043.webp)
INF-41
9-2. Operation flow chart after replacement of major parts
9-2-1. DIGITAL MAIN P.C.Board
Refer to item
“7. Save and write
EEPROM data” on page INF-29
about save and writing procedure.
Backup the XP/CAM/SYS EEPROM data
Please operate Following
< Procedure 1 >
Please operate following < Procedure 2 >
Replace the DIGITAL MAIN P.C.Board
The Hour Meter information
becomes “0”
Please operate Following
< Procedure 2 >
Write the Setting menu data (USER FILE) to SD memory card.
Is it possible to backup the
data of XP EEPROM ?
Is it possible to backup the
data of CAM EEPROM ?
Is it possible to backup the
data of SYS EEPROM ?
NO
YES
NO
YES
NO
YES
Load the backup data to new P.C.Board
Write the Scene file data to SD memory card.
Please operate Following
< Procedure 2 >