Table 6: XMT1000 modbus register map - revision 4.19
Reg #
in hex
Access
level
Register ID
Description
Units
RO/
RW
Size in
bytes
Format
MAIN Dout1 real RW
2000
2000
Operator
eDout1_PulseValue
Output_1
pulse value
17
RW
4
(IEEE 32 bit)
2002
Operator
eDout1_PulseTime
Output_1
pulse time
10
RW
4
(IEEE 32 bit)
2004
Operator
eDout1_freqBaseValue
Output_1
frequency base value
1, 9, 14, 17, 20 RW
4
(IEEE 32 bit)
2006
Operator
eDout1_freqFullValue
Output_1
frequency full value
1, 9, 14, 17, 20 RW
4
(IEEE 32 bit)
2008
Operator
eDout1_AlarmValue
Output_1
alarm value
1, 9, 14, 17, 20 RW
4
(IEEE 32 bit)
200A
Operator
eDout1_controlValue
Output_1
control output value
17
RW
4
(IEEE 32 bit)
MAIN Dout1 int RW
2100
2100
Operator
eDout1_PulseTestValue
Output_1
test pulse value
Unitless
RW
4
INT32
2102
Operator
eDout1_freqFullfreq
Output_1
frequency full frequency
6
RW
4
INT32
2104
Operator
eDout1_freqTestValue
Output_1
test frequency value
6
RW
4
INT32
2106
Operator
eDout1_freqErrValue
Output_1
frequency error
handling value
6
RW
4
INT32
2180
2180
Operator
eDout1_Type
Output_1
type
Unitless
RW
4
INT32
2182
Operator
eDout1_PulseUnit
Output_1
pulse value unit code
Unitless
RW
4
INT32
2184
Operator
eDout1_PulseErr
Output_1
pulse error handling
Unitless
RW
4
INT32
2186
Operator
eDout1_freqAddress
Output_1
frequency measurement
register address
Unitless
RW
4
INT32
2188
Operator
eDout1_freqErr
Output_1
frequency error handling
Unitless
RW
4
INT32
40