background image

9

FOLD 72 FIRE TABLE CE Electronic Ignition | Installation & Owner’s Manual

LIGHTING YOUR FIRE PIT

 

WARNINGS

:

Failure to follow these instructions exactly may result in fire or 

explosion causing property damage, personal injury or loss 

of life.

Before operating the appliance, check all around the appliance 

area and on the surrounding floor for the smell of gas - some 

gas is heavier than air and may settle on the floor in the event 

of a leak.  IF YOU SMELL GAS, follow the safety instructions 

on page 1 of this manual.

This appliance is equipped with an ignition device that 

automatically lights the pilot.  Do not try to light the pilot 

manually.

The main gas valve in this appliance is not serviceable and 

does not have any control knobs or switches to operate.  Do 

not remove the heat shields covering the valve and electronic 

devices. Do not try to repair or modify the valve, as doing 

so may result in a fire or explosion.  Call a qualified service 

technician if you have any safety concerns.

Do not use this appliance if any part of it has been under 

water.  Immediately call a qualified service technician to 

inspect the appliance and to replace any part of the control 

system and any gas control that has been under water.

Improper installation, adjustment, alteration, service or 

maintenance can result in injury or property damage. For 

assistance or additional information, consult a qualified 

installer, service agency or the gas supplier.

Do not store or use gasoline or other flammable vapors or 

liquids in the vicinity of this appliance.

INITIAL LIGHTING INSTRUCTIONS

Before placing burner assembly into a housing:

1.  Purge air from the supply line.
2.  Test for leaks in each of the following locations:

•  The gas supply line connection to the main valve;
•  The Burner connections and pilot;
•  All joints on the valve and control body;
•  All field made joints and gas shutoff valves;
•  All factory made joints and connections.

3.  You may check for gas leaks using one of the following methods only:

•  Soap and water solution.  WARNING:  If using a soap and water solution to test 

for leaks, DO NOT spray the solution onto electronic parts;

•  An approved leak testing spray;
•  An electronic sniffer.  NOTE: Remove any excess pipe compound from 

connections if using this method, as the compound can set off electronic sniffers.

DANGER: NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

Summary of Contents for FOLD 72

Page 1: ...bon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home WARNING Improper installation adjustment alter...

Page 2: ...fixed piping system The installation must conform to local and or national codes 3 Never leave the fire unattended 4 Keep the appliance area clear and free from combustible materials gasoline and oth...

Page 3: ...ps p 4 5 GAS ELECTRICAL Supply lines are routed through the base of the unit and must be installed by licensed trades 6 MEDIA TOPPINGS Review correct placement p 7 8 CAUTION where applicable COR TEN S...

Page 4: ...1210 gr h Burner Pressure 8 7 mbar 25 mbar Orifice Size 26 43 Burner Ports 35 35 Port Size 1 8 3 mm 1 8 3 mm Electrical 230V Outdoor Receptacle Dedicated Circuit with Wall Switch Burner connects via...

Page 5: ...5 FOLD 72 FIRE TABLE CE Electronic Ignition Installation Owner s Manual MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 0 CLEARANCE BELOW 4 7 2 4 4 4 1829 mm 102 mm 102 mm...

Page 6: ...agram on page 3 2 Connect the Burner Assembly to the gas supply using the supplied flex connector following the instructions on p 9 3 Carefully leak test all connections following the procedure on p 9...

Page 7: ...ING MEDIA VARIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG LAVA ROCK LP FILL BURNER MEDIA TRAY VENTILATION GAP DO NOT BLOCK CAUTION Do not use any media o...

Page 8: ...uel pressures Pipes of a smaller size than the heater inlet gas connection must not be used If utilizing used pipe verify that its condition is clean and comparable to a new pipe Test all gas supply l...

Page 9: ...qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or...

Page 10: ...nce including near the floor If you smell gas STOP Follow the instructions on page 1 of this manual If you do not smell gas continue to the next step 6 Turn the manual gas control valve to the ON posi...

Page 11: ...de pages 12 13 BURNER ELEMENT AND PILOT Keep the burner and pilot area clean by vacuuming or brushing at least twice a year Make sure the burner porting and burner air openings are free of obstruction...

Page 12: ...IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is s...

Page 13: ...is clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace pi...

Page 14: ...2 LIN 36 Burner Tube LIN 36 ASSY same 2a Air Shutter 3 Orifice FIT ORI 26 FIT ORI 43 4 Media Tray LIN 36 ASSY A same 5 Burner Tray LIN 36 ASSY B same 6 Control Box Brackets LIN 36 ASSY C same 7 Pilot...

Page 15: ...using CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Union 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignition Cont...

Page 16: ...iagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E 410 OR PIL E 410LP IGNITION CONT...

Page 17: ...appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged by accident neglect misuse abuse...

Reviews: