INSTALLATION (CONTINUED)

Running the unit on voltages which are not within the range may
cause overheating and motor burn out. Heavy loads require that the
voltage at motor terminals be no less than the voltage specified.

GROUNDING INSTRUCTIONS
WARNING:

Improper connection of equipment grounding con-

ductor can result in the risk of electrical shock. Equipment should
be grounded while in use to protect operator from electrical shock.

Check with a qualified electrician if grounding instructions are not
understood or if in doubt as to whether the tool is properly
grounded.

This tool is equipped with an approved 3-conductor cord rated up
to 150V and a 3-prong grounding type plug rated at 115V (See
Figure 1) for your protection against shock hazards.

Grounding plug should be plugged directly into a properly
installed and grounded 3-prong grounding-type receptacle, as
shown (Figure 1).

Do not remove or alter grounding prong in any manner. In the
event of a malfunction or breakdown, grounding provides a path
of least resistance for electrical shock.

WARNING:

Do not permit fingers to touch the terminals of plug

when installing or removing from outlet.
Plug must be plugged into matching outlet that is properly
installed and grounded in accordance with all local codes and
ordinances. Do not modify plug provided. If it will not fit in outlet,
have proper outlet installed by a qualified electrician.
Inspect tool cords periodically, and if damaged, have repaired by
an authorized service facility.
Green (or green and yellow) conductor in cord is the grounding
wire. If repair or replacement of the electric cord or plug is neces-
sary, do not connect the green (or green and yellow) wire to a live
terminal.
Where a 2-prong wall receptacle is encountered, it must be
replaced with a properly grounded 3-prong receptacle installed in
accordance with National Electric Code and local codes and ordi-
nances.

WARNING:

This work should be performed by a qualified electrician.

A temporary 3-prong to 2-prong grounding adapter (See Figure 2)
is available for connecting plugs to a two pole outlet if it is 
properly grounded.

Do not use a 3-prong to 2-prong grounding adapter unless permit-
ted by local and national codes and ordinances.

(A 3-prong to 2-prong grounding adapter is not permitted in
Canada.) Where permitted, the rigid green tab or terminal on the
side of the adapter must be securely connected to a permanent
electrical ground such as a properly grounded water pipe, a prop-
erly grounded outlet box or a properly grounded wire system.

Many cover plate screws, water pipes and outlet boxes are not
properly grounded. To ensure proper ground, grounding means
must be tested by a qualified electrician.

EXTENSION CORDS

The use of any extension cord will cause some drop in voltage
and loss of power.

Wires of the extension cord must be of sufficient size to carry
the current and maintain adequate voltage.

Use the table to determine the minimum wire size (A.W.G.)
extension cord.

Use only 3-wire extension cords having 3-prong grounding
type plugs and 3-pole receptacles which accept the tool plug.

If the extension cord is worn, cut, or damaged in any way,
replace it immediately.

EXTENSION CORD LENGTH

Wire Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.W.G.
Up to 25 ft.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
25-100 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
100-150 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

NOTE:

Using extension cords over 150 ft. long is not recommended.

OPERATION

Refer to Figures 3, 4, 5 and 6.

WARNING:

Read and understand operating instructions and

parts manual before operating this machine.

CAUTION:

The operation of any power tool can result in foreign

objects being thrown into the eyes, which can result in severe eye
damage. Always wear safety glasses complying with United States
ANSI Z87.1 (shown on package) before commencing power tool
operation.

THE LASER GUIDE

Your tool is equipped with a laser guide, a battery powered device
using Class II laser beams. The laser beams will enable you to pre-
view the drill bit path on the workpiece to be drilled before you
begin your operation.

Laser Radiation: Avoid direct eye contact. A
Laser light is radiated when the laser guide is

turned on. Avoid direct eye contact. Always turn off the laser and
unplug the drill press from the power source before making any
adjustments. 

A laser pointer is not a toy and should not come into hands of
children. Misuse of this appliance can lead to irreparable eye
injuries.

Any adjustments to increase the laser power is forbidden.

When using the laser pointer, do not point the laser beam
towards people and / or reflecting surfaces. Even a laser beam
of lower intensity may cause eye damage. Therefore, do not
look directly into the laser beam.

If the laser pointer is stored for more than three months with-
out use, please remove the batteries to avoid damage from
possibly leaking batteries.

The laser pointer includes no user serviceable components.
Never open the housing for repair or adjustments.

On units equipped with the Laser-Guide attachment, repairs
shall only be carried out by the laser manufacturer or autho-
rized agent.

Laser Warning label: Max output 1mW DIODE LASER: 650nm,
Complies with 1040. 10e.

Palmgren Operating Manual & Parts List

80110B

Figure 1 – 3-Prong Receptacle

Properly Grounded Outlet

Grounding Prong

3-Prong Plug

Figure 2 – 2-Prong Receptacle with Adapter

Grounding Lug

Adapter

3-Prong Plug

2-Prong Receptacle

Make sure this is 
Connected to a known
Grounded Receptacle

Summary of Contents for 80110B

Page 1: ...operating manual parts list 80110B 10 BENCH MODEL DRILL PRESS Read carefully and follow all safety rules and operating instructions before first use of this product 36313 00 0712...

Page 2: ...e 15 8 Overall height 27 5 Weight 70 lbs Motor 1 3 HP 120V 1725 RPM 4 1A SAFETY RULES Before any work is done carefully read the cautions listed Working safely prevents accidents WARNING Some dust cre...

Page 3: ...over column Place bottom end of rack inside beveled edge of column flange Slide rack retaining ring Ref No 16 over column with beveled edge down Position ring against top of rack so that rack is in b...

Page 4: ...pes and outlet boxes are not properly grounded To ensure proper ground grounding means must be tested by a qualified electrician EXTENSION CORDS The use of any extension cord will cause some drop in v...

Page 5: ...g handle Ref No 10 and rotate table to desired position and retighten handle Tilting work table Loosen hex head bolt Ref No 6 Tilt table to desired angle up to 45 and retighten hex head bolt To obtain...

Page 6: ...ally lubricate the splines grooves in the spindle and the rack teeth on the quill as follows Lower quill assembly Figure 6 Ref No 54 all the way down Apply lubricant around the inside of the hole in t...

Page 7: ...proper belt tension 3 Workpiece not supported or clamped properly The batteries have become uncharged CORRECTIVE ACTION 1 Check wiring fuse or circuit breaker 2 Replace switch 3 Replace motor Replace...

Page 8: ...8 Figure 5 Replacement Parts Illustration for Base Palmgren Operating Manual Parts List 80110B 1 10 13 5 4 3 2 11 15 16 17 18 12 14 9 8 7 6...

Page 9: ...d Bolt 3 6 12 1 75 x 25mm Hex Head Bolt 1 7 12mm Lock Washer 1 8 Table 36193 00 1 9 Pinion Gear and Shaft 36194 00 1 10 Locking Handle 36195 00 1 11 Scale 36196 00 1 12 Bracket 36197 00 1 13 Crank Arm...

Page 10: ...List 80110B Figure 6 Replacement Parts Illustration for Head 38 3 39 11 25 24 33 34 28 29 27 21 2 1 6 3 5 7 8 9 15 4 16 17 18 26 23 17 22 10 20 19 30 31 32 40 41 15 43 32 42 37 36 35 10 51 52 53 50 4...

Page 11: ...9 00 1 29 Laser guide assembly 36220 00 1 30 Knob 36221 00 1 31 Depth stop collar assembly 36222 00 1 32 Knob 36223 00 2 33 Pointer 36224 00 1 34 Pin 36225 00 1 35 Damper 36226 00 4 36 Line cord 36227...

Page 12: ...ars Work stands 2 years Arbor presses 2 years Metal forming equipment 2 years Accessories 1 year The obligation of Palmgren is limited solely to the repair or replacement at our option at its factory...

Page 13: ...evitar posibles peligros de incendio ESPECIFICACIONES Tama o del portaherramientas 1 5 13 mm 1 16 1 2 Ahusamiento del husillo JT33 Recorrido del husillo 6 3 cm Di metro del eje hueco 4 cm Di metro del...

Page 14: ...uina Prot jalas de posibles lesiones Apague la m quina si se atasca La broca se atasca cuando se entierra muy profundamente dentro de la pieza de trabajo La fuerza del motor la mantiene enterrada en e...

Page 15: ...r resistencia al choque el ctrico ADVERTENCIA No permita que los dedos toquen los terminales o el enchufe cuando se est n instalando o removiendo del tomacorriente El enchufe se debe enchufar en el to...

Page 16: ...tornillos a cada lado del m dulo del l ser y gire los l seres hasta que las l neas se inter secten en el centro de la X Los tornillos A aflojan el l ser cerca del eje Al aflojar los tornillos B la l...

Page 17: ...mordazas del portaherramientas Apriete el portaherramientas con la cu a de ste Aseg rese de apre tarlo usando las tres posiciones en el cuerpo del portaherramientas y remueva la cu a Use solamente la...

Page 18: ...o sujeta correctamente Las baterias est n descargadas 1 Ajuste la tensi n 2 Lubrique el husillo Vea Lubricaci n 3 Apriete la tuerca de la polea 4 Apriete el tornillo de fijaci n en la polea 1 Cambie l...

Page 19: ...19 Manual de Operaci n y Lista de Partes de Palmgren 80110B NOTAS...

Page 20: ...de acabado 2 a os Sierras de banda 2 a os Plataformas de soporte 2 a os Prensas de husillo 2 a os Equipos de formado met lico 2 a os Accesorios 1 a o La obligaci n de Palmgren est limitada nicamente...

Reviews: