background image

Water treatment 

system’s operating water tempe- 

rature is between minimum 

5˚C (41˚F) and maxi- 

mum 

40˚C (104˚F). It has risk of freezing to operate 

the device below 

5˚C as it carries risk of damage to 

filters when operated at above 

40˚C.

 

It is necessary to select a suitable location first for 
installation of water treatment device. It must be 
considered during selection that installation place 
should be close to cold water line of the RO device 
and to the drainage and sufficient space should be 
left for working in case of malfunction and filter 
replacement.

 

Water treatment device is designed for water with 
specifications close to tap water, whose inlet con- 
ductivity is max. 600 ppm and the turbidity is max 
3 NTU. If raw water source and specifications are 
unknown, the raw water should be sent for analysis 
before installation of the device in order to check 
the suitability.

 

If the device is used beyond the limit values men- 
tioned in technical specification part of the 

users’ 

manual, the requested quality will not be achieved 
for product water. Usage of such feed water will 
cause variation in replacement periods of filters 
and membrane.

 

Inlet pressure is between 3 - 6 bar for water treat- 
ment devices without pump and between 1 - 6 bar 
for water treatment devices with pump. The opti- 
mum working pressure is 3 bar. In case the inlet 
pressure is above 4 bar, it is recommended to ins- 
tall a pressure reducer to prevent more wastewa- 
ter discharge. Do not connect the device to power 
socket before it is installed.Our company will not be 
liable for any problems caused by non-observance 
of the above warnings.

 

TREATMENT DEVICE FLOW SCHEME

 

WATER SUPPLY 

 

FAUCET

 

TANK

 

1.

 

2.

 

3.

 

4.

 

PRE-FİLTER

 

FIRST CARBON 
SEDIMENT FILTER / CTO

 

R.O (50-100 GPD)

 

5.

 

6.

 

7.

 

8.

 

SECOND CARBON

 

RAW WATER 
PUMP 
WASTEWATER

 

9.

 

STORAGE TANK

 

10.

 

PRESSURE REDUCER

 

11.

 

FAUCET

 

6

 

| ENJOY SMART

 

 

 

POINTS TO BE CONSIDERED BEFORE INSTALLATION OF THE DEVICE

 

 

 

Summary of Contents for ENJOY SMART Series

Page 1: ... COMMERCIAL DOMESTIC RO COMMERCIAL DOMESTIC RO PALLAS ENJOY SMART MANUAL ...

Page 2: ...r for you to lead a healthy life The product is manufactured in modern facilities without giving no harm to environment It is recommended that you read the manual very carefully before using the product whichismanufacturedstudiouslyin Thankyouforchoosing our product DEFINITIONS OF SYMBOLS USED IN MANUAL PACKAGING INFORMATION Packing materials are manufactured from recyclable materials by national ...

Page 3: ...FTHE DEVICE 6 BOX CONTENTS ANDASSEMBLY PARTS 7 DEVICE PROPERTIES 8 INSTALLATION AND ASSEMBLY 9 MAINTENANCE AND CLEANING 11 START UP AFTER MAINTENANCE 14 WARRANTY CONDITIONS 15 IMPORTANT SAFETY AND ENVIRONMENTAL INSTRUCTIONS CONSUMER RIGHTS 16 TROUBLESHOOTING 17 FREQUENTLY ASKED QUESTIONS 18 AUTHORIZED SERVICES AND SPARE PARTS SUPPLIERS 18 ...

Page 4: ...esva rious technical knowledge and experience such as product water quality raw water analysis type of membrane etc Reverse osmosis practices Water treatment device is designed to work with minimum water pressure It does not require che mical use and produces quality water It is manu factured as a compact device that can easily be installed anywhere thanks to minimum dimensions RO treatment device...

Page 5: ... the drainage through wastewater partof membrane 5th stage Last carbonfilter postcarbon Water runsthroughthecarbonfilteratthelaststageto provide clean and extremely safe drinking water STAGESOF CLEAN WATER PRODUCTION IN REVERSE OSMOSISSYSTEM Feed water pressure must be minimum 3 bar for reverse osmosis system to work If the feed water pressure is not sufficient the system can be rein forcedwithapu...

Page 6: ...heck the suitability If the device is used beyond the limit values men tioned in technical specification part of the users manual therequestedqualitywillnotbeachieved forproductwater Usage ofsuch feed water will cause variation in replacement periods of filters and membrane Inlet pressure is between 3 6 bar for water treat ment devices without pump andbetween 1 6 bar for water treatment devices wi...

Page 7: ... Sediment Filter 75 GPD Membrane 2 2 Gallon Storage Tank 9 10 Metal Ball Valve 1 4 75 GPD Dynamic Pump available in model withpump 24 Volt 1 5 Amper Adapter available in model withpump Feed water connection part Automatic shut off valve Tube UsersManualandWarrantyCertificate 11 12 13 14 15 USERS MANUAL 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 MANUAL BOX CONTENTS AND ASSEMBLY PARTS ...

Page 8: ...EandNSFstandards Theequipmentsarecertified 8 ENJOY SMART WITH PUMP WITH OUT PUMP Min OperatingWaterTemperature 5 C 5 C Max OperatingWaterTemperature 40 C 40 C Min InletPressure 1 bar 3 bar Max InletPressure 6 bar 6 bar Max InletTDS ppm 500 ppm 500 ppm InletDiameter 6 mm 6 mm DEVICE PROPERTIES ...

Page 9: ...aesthetics Youcanstarttodrill countertop or sink after leaving enough space for installation of seal nutandunionatthebottomofcountertoporsink Otherwise youmay drill the wrong place 2 If you drill marble granite ceramic laminate or sheet metal sink first you should use 5 mm drilling bit and then 12 mm drilling bit respecti vely Thedrillmustbeoperatedatlowspeedandwithoutimpact Ifthe counteriscovered...

Page 10: ...aucet after mounting the faucet and drain line Loosen and pull out stem nut on outlet of the post carbon filter Put the nut on tube and tighten firmly Insert the other side of the tube into res pectively yellow nut and collet placed under the faucet Pushthetubetothefaucet andtightenthe nut firmly Yellow nut Faucet embodiments Hose connection Hose HOSE CONNECTIONSCHEME Asshowninfigure A Waterinlet ...

Page 11: ...fiedwaterforcooking preparingtea coffeeetc Incaseofwaterleaks brokenfiltersetc turnoffthevalve ofwatersupplyandcorrectthefaults REPLACEMENTPERIODSOFCARTRIDGEFILTERS If feeding tube is damaged it should be replaced withaspeciallypreparedtubeortubesetsupplied bythe manufacturer orauthorised service 12 5 Micron Spun Sediment Filter It should be replaced approximately every 6 months depending on the w...

Page 12: ...anereplacementandhousing sanitisationasseeninfigures Open drinking water faucet Loose the union of the membrane housing on the water inlet side and disconnect tubing from the housing Unscrew the membrane housing from the cap with pliers and displace the used membra ne Clean the membrane housing with disinfe ctant bleach solution and rinse the housing Wet or wipe the O ring at the bottom of thenew ...

Page 13: ... certificate of warranty to be void PRECAUTIONSTOUSEYOURDEVICELONGER To ensure that your device functions properly and to prolong the life of the device the following points must be taken into consideration Otherwise the warranty will be voided Donotusewithwaterthathastemperatureabo ve 40 C Place or fix the device on a flat surface Do not touch the valves on the device except when necessary Itisre...

Page 14: ...otgetdamagedduetoheat humidityordust Keepitoutofsunexposure Youcan get support from our authorized services to avoid unexpected damages during transporta tion and handling Afterturningonthevalves turnonthewatersupp ly OpenROfaucetandchecktheentiresystemfor leaks Now you can enjoy the quality water safely Turn on the mini valveofthewater supplyasshownin the figure SupplyofSparePartsUnder OutofWarra...

Page 15: ...uthorized service Damages or defects due to unknown material found inside the product Problems resulting from failure to comply with installation operationormaintenanceinstructi onsordrawings orimproperinstallation opera tion or maintenance Damages and defects resulting from using non originalsparepartsandaccessories Damages and defects resulting from running the productwithoutwaterorinadequatewat...

Page 16: ...s to use the right of free repair and Theproductre failsduringwarrantyperiod The maximum time required for repair is exce eded Ifrepairisnotpossibleanddeterminedwitha report by an authorized service seller manufac turer or importer Consumer may request from the seller to refund discount at the defect rate or replace the product with non defective products if possible The seller cannot refuse the c...

Page 17: ...E IS WASTE WATER FLOW Too low or high pressure Pumpshouldbeused forwaterwithlowpressureas pressure reducer is recommended for water withhigh pressure Faulty check valve Replace check valve LEAKS IN DEVICE Faulty connection Check all connections Not properly cut edges of tubes Remove leaking tubes cut the edges straightly and replace them Not properly fitted gaskets Fit the gaskets UNPLEASANT ODOR ...

Page 18: ...replace filtersmyself Yes youcan However anyotherpractisenotper formed by a service provider will cause the war ranty to be voided If the service is provided by an authorised personnel the device will continue to be underwarrantytilltheexpirationdateofwarranty PWG www pwg be Alamo www alamowaterpoland com EWT www ewt fr Euraqua www euraqua com Aquina Wassertechnik Gmbh www aquina wassertechnik de ...

Page 19: ...vice if warranty has already expired In case of not being repaired within 10 workdays the manufacturer or importer must supply a similar product to the consumer until the product is repaired In the event that the product is defected within warranty perion the days when the product remains in the service are added to warranty period 6 Defectsresulting from contraryusage to instructions specified in...

Page 20: ...ent Method 2014 35 EU Applicable CE Directives 2014 35 EU Applicable International Technical Standards EN 60730 2 15 2010 A11 2011 TS EN 60335 1 TS EN 60335 1 AC TS EN 60335 1 2012 A11 ESLI ENDÜSTRIYEL URUNLER PAZARLAMA SANAYI VE TICARET LIMITED SIRKETI Address Antalya Organize Sanayi Bölgesi 1 Kısım Antalya Bulvarı No 36 07190 Döşemealtı ANTALYA TURKEY TEL 0 242 417 76 20 E MAIL esli esli com tr ...

Reviews: