background image

USERS MANUAL |

 

17

 

 

Problem 

Possible Cause 

Action

 

 
 

THE DEVICE DOES 
NOT WORK

 

 

No water supply

 

Ceck if water enters the system

 

Faulty connection to power 
source

 

Check the electrical connections

 

Damaged adapter

 

Replace it or contact service

 

Faulty low pressure switch

 

Replace it or contact service

 

 

NO PRODUCT (PURIFIED) 
OR WASTE WATER FLOW

 

 

Water supply valve is closed

 

Open the water supply valve

 

 

Clogged filters

 

Replace the clogged filters.

 

Replacement of flow restrictor is recommended.

 

SLOW OR NO PRODUCT 
WATER FLOW BUT 
THERE IS WASTE WATER 
FLOW

 

Clogged or exhausted membrane

 

Replace the membrane

 

Faulty check valve

 

Replace check valve

 

Faulty storage tank

 

Replace the tank

 

 

TANK IS FULL BUT 
THERE IS WASTE WATER 
FLOW

 

 

Too low or high pressure

 

 

Pump should be used for water with low pressure as 
pressure reducer is recommended for water with high 
pressure.

 

Faulty check valve

 

Replace check valve

 

 

 

LEAKS IN DEVICE

 

 

Faulty connection

 

Check all connections

 

Not properly cut edges of tubes

 

Remove leaking tubes, cut the edges straightly and 
replace them.

 

Not properly fitted gaskets

 

Fit the gaskets

 

 

 

UNPLEASANT ODOR 
AND TASTE OF PURIFIED 
WATER

 

 

Exhausted cartridge filters

 

Replace the filters if they are used up for 6 months.

 

 

Low pH level

 

Ideal pH level is between 7-8. If lower, ask your service 
for installing a pH meter. (Not covered by warranty)

 

Bacteria in the device

 

Disinfect your device

 

 

NO WASTE WATER FLOW

 

 

Clogged flow restrictor

 

Replace flow restrictor

 

Filter maintenance date has 
expired

 

Replace filters and membrane element

 

SLOWLY FLOW OF 
PURIFIED WATER FRO 
FAUCET

 

 

Faulty storage tank

 

 

 

Replace the tank

 

 

 

TROUBLESHOOTING

 

 

Summary of Contents for ENJOY SMART Series

Page 1: ... COMMERCIAL DOMESTIC RO COMMERCIAL DOMESTIC RO PALLAS ENJOY SMART MANUAL ...

Page 2: ...r for you to lead a healthy life The product is manufactured in modern facilities without giving no harm to environment It is recommended that you read the manual very carefully before using the product whichismanufacturedstudiouslyin Thankyouforchoosing our product DEFINITIONS OF SYMBOLS USED IN MANUAL PACKAGING INFORMATION Packing materials are manufactured from recyclable materials by national ...

Page 3: ...FTHE DEVICE 6 BOX CONTENTS ANDASSEMBLY PARTS 7 DEVICE PROPERTIES 8 INSTALLATION AND ASSEMBLY 9 MAINTENANCE AND CLEANING 11 START UP AFTER MAINTENANCE 14 WARRANTY CONDITIONS 15 IMPORTANT SAFETY AND ENVIRONMENTAL INSTRUCTIONS CONSUMER RIGHTS 16 TROUBLESHOOTING 17 FREQUENTLY ASKED QUESTIONS 18 AUTHORIZED SERVICES AND SPARE PARTS SUPPLIERS 18 ...

Page 4: ...esva rious technical knowledge and experience such as product water quality raw water analysis type of membrane etc Reverse osmosis practices Water treatment device is designed to work with minimum water pressure It does not require che mical use and produces quality water It is manu factured as a compact device that can easily be installed anywhere thanks to minimum dimensions RO treatment device...

Page 5: ... the drainage through wastewater partof membrane 5th stage Last carbonfilter postcarbon Water runsthroughthecarbonfilteratthelaststageto provide clean and extremely safe drinking water STAGESOF CLEAN WATER PRODUCTION IN REVERSE OSMOSISSYSTEM Feed water pressure must be minimum 3 bar for reverse osmosis system to work If the feed water pressure is not sufficient the system can be rein forcedwithapu...

Page 6: ...heck the suitability If the device is used beyond the limit values men tioned in technical specification part of the users manual therequestedqualitywillnotbeachieved forproductwater Usage ofsuch feed water will cause variation in replacement periods of filters and membrane Inlet pressure is between 3 6 bar for water treat ment devices without pump andbetween 1 6 bar for water treatment devices wi...

Page 7: ... Sediment Filter 75 GPD Membrane 2 2 Gallon Storage Tank 9 10 Metal Ball Valve 1 4 75 GPD Dynamic Pump available in model withpump 24 Volt 1 5 Amper Adapter available in model withpump Feed water connection part Automatic shut off valve Tube UsersManualandWarrantyCertificate 11 12 13 14 15 USERS MANUAL 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 MANUAL BOX CONTENTS AND ASSEMBLY PARTS ...

Page 8: ...EandNSFstandards Theequipmentsarecertified 8 ENJOY SMART WITH PUMP WITH OUT PUMP Min OperatingWaterTemperature 5 C 5 C Max OperatingWaterTemperature 40 C 40 C Min InletPressure 1 bar 3 bar Max InletPressure 6 bar 6 bar Max InletTDS ppm 500 ppm 500 ppm InletDiameter 6 mm 6 mm DEVICE PROPERTIES ...

Page 9: ...aesthetics Youcanstarttodrill countertop or sink after leaving enough space for installation of seal nutandunionatthebottomofcountertoporsink Otherwise youmay drill the wrong place 2 If you drill marble granite ceramic laminate or sheet metal sink first you should use 5 mm drilling bit and then 12 mm drilling bit respecti vely Thedrillmustbeoperatedatlowspeedandwithoutimpact Ifthe counteriscovered...

Page 10: ...aucet after mounting the faucet and drain line Loosen and pull out stem nut on outlet of the post carbon filter Put the nut on tube and tighten firmly Insert the other side of the tube into res pectively yellow nut and collet placed under the faucet Pushthetubetothefaucet andtightenthe nut firmly Yellow nut Faucet embodiments Hose connection Hose HOSE CONNECTIONSCHEME Asshowninfigure A Waterinlet ...

Page 11: ...fiedwaterforcooking preparingtea coffeeetc Incaseofwaterleaks brokenfiltersetc turnoffthevalve ofwatersupplyandcorrectthefaults REPLACEMENTPERIODSOFCARTRIDGEFILTERS If feeding tube is damaged it should be replaced withaspeciallypreparedtubeortubesetsupplied bythe manufacturer orauthorised service 12 5 Micron Spun Sediment Filter It should be replaced approximately every 6 months depending on the w...

Page 12: ...anereplacementandhousing sanitisationasseeninfigures Open drinking water faucet Loose the union of the membrane housing on the water inlet side and disconnect tubing from the housing Unscrew the membrane housing from the cap with pliers and displace the used membra ne Clean the membrane housing with disinfe ctant bleach solution and rinse the housing Wet or wipe the O ring at the bottom of thenew ...

Page 13: ... certificate of warranty to be void PRECAUTIONSTOUSEYOURDEVICELONGER To ensure that your device functions properly and to prolong the life of the device the following points must be taken into consideration Otherwise the warranty will be voided Donotusewithwaterthathastemperatureabo ve 40 C Place or fix the device on a flat surface Do not touch the valves on the device except when necessary Itisre...

Page 14: ...otgetdamagedduetoheat humidityordust Keepitoutofsunexposure Youcan get support from our authorized services to avoid unexpected damages during transporta tion and handling Afterturningonthevalves turnonthewatersupp ly OpenROfaucetandchecktheentiresystemfor leaks Now you can enjoy the quality water safely Turn on the mini valveofthewater supplyasshownin the figure SupplyofSparePartsUnder OutofWarra...

Page 15: ...uthorized service Damages or defects due to unknown material found inside the product Problems resulting from failure to comply with installation operationormaintenanceinstructi onsordrawings orimproperinstallation opera tion or maintenance Damages and defects resulting from using non originalsparepartsandaccessories Damages and defects resulting from running the productwithoutwaterorinadequatewat...

Page 16: ...s to use the right of free repair and Theproductre failsduringwarrantyperiod The maximum time required for repair is exce eded Ifrepairisnotpossibleanddeterminedwitha report by an authorized service seller manufac turer or importer Consumer may request from the seller to refund discount at the defect rate or replace the product with non defective products if possible The seller cannot refuse the c...

Page 17: ...E IS WASTE WATER FLOW Too low or high pressure Pumpshouldbeused forwaterwithlowpressureas pressure reducer is recommended for water withhigh pressure Faulty check valve Replace check valve LEAKS IN DEVICE Faulty connection Check all connections Not properly cut edges of tubes Remove leaking tubes cut the edges straightly and replace them Not properly fitted gaskets Fit the gaskets UNPLEASANT ODOR ...

Page 18: ...replace filtersmyself Yes youcan However anyotherpractisenotper formed by a service provider will cause the war ranty to be voided If the service is provided by an authorised personnel the device will continue to be underwarrantytilltheexpirationdateofwarranty PWG www pwg be Alamo www alamowaterpoland com EWT www ewt fr Euraqua www euraqua com Aquina Wassertechnik Gmbh www aquina wassertechnik de ...

Page 19: ...vice if warranty has already expired In case of not being repaired within 10 workdays the manufacturer or importer must supply a similar product to the consumer until the product is repaired In the event that the product is defected within warranty perion the days when the product remains in the service are added to warranty period 6 Defectsresulting from contraryusage to instructions specified in...

Page 20: ...ent Method 2014 35 EU Applicable CE Directives 2014 35 EU Applicable International Technical Standards EN 60730 2 15 2010 A11 2011 TS EN 60335 1 TS EN 60335 1 AC TS EN 60335 1 2012 A11 ESLI ENDÜSTRIYEL URUNLER PAZARLAMA SANAYI VE TICARET LIMITED SIRKETI Address Antalya Organize Sanayi Bölgesi 1 Kısım Antalya Bulvarı No 36 07190 Döşemealtı ANTALYA TURKEY TEL 0 242 417 76 20 E MAIL esli esli com tr ...

Reviews: