Page 2: ... element removal is as follows 4 2 1 UH211C series cover service 203 mm 8 in for length 8 338 mm 13 3 in for length 13 and 508 mm 20 in for length 20 housings 4 2 2 UH211H series head service 100 mm 3 9 in for all lengths 4 2 3 The UH211 housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded differential pressure devices when ...

Page 3: ...ate new labels 6 Differential pressure devices Reference should be made to product literature for dimensions operating parameters part numbering ordering information and specifications 6 1 Differential pressure devices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start red button exten...

Page 4: ... 1 1 For UH211C series cover service Open the vent plug 7 at the top of the filter one and one half turns Open partially the blanking plug 6b in the filter head and drain fluid into a suitable waste receptacle This sequence may be long for high viscosity fluids Replace and torque tighten the blanking plug to 38 ft lb or 54Nm Unscrew and remove cover 3 from tube 2 counter clockwise when viewed from...

Page 5: ...ltered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in u...

Page 6: ...UH211 UH211 Series HIGH PRESSURE FILTERS s e r v i c e instructions 6 2 4 8 6b 3 1 Figure 2 5 7 6 Inlet Outlet Not shown on this diagram Not shown on this diagram ...

Page 7: ...UH211 UH211 Series HIGH PRESSURE FILTERS s e r v i c e instructions 7 ...

Page 8: ...d plants throughout the world For Pall representatives in your area please go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid Pall Industrial Manufactur...