Note: Painting of the filter housing is optional. The coating on
the filter housing is a suitable painting base. Cover the
differential pressure warning device and nameplate if painting
of the housing takes place.

4.8

Bleed the filter.
4.8.1

UH211C series (cover service): Bleed the filter
by opening the vent plug (7) at the top of filter
one and one half turns. Jog system and fill filter
until all air bleeds through the plug, then torque
tighten the vent plug to 12 ft/lb or 16 Nm.

4.8.2 

UH211H series (head service): Bleed the filter
by opening the blanking plug (6b) one and
one-half turns. Jog system and fill filter until all
air bleeds through the plug, then torque
tighten the blanking plug to 40 ft/lb or 54 Nm. 

Pressurize system fully and check for leaks; if leaks occur refer
to section 5.

5

Routine maintenance

5.1

Pall

filters do not normally require special attention

except for periodic monitoring of the differential pressure
warning device. Schedule replacement of filter element
every six months or sooner, and have ample supply of
spare elements available. 

5.2

If external leakage is noted, replace O-ring at leak. If
leakage persists, check sealing surfaces for scratches 
or cracks; replace any defective parts. 

5.3

Differential pressure devices actuate when the element
needs changing or because of high fluid viscosity in
'cold start' conditions. If 'cold start' conditions exist, 
see Section 6.2 and 6.3.

5.4

A dirty system can quickly plug a new filter element,
especially with 

Pall

high efficiency filter media. It may

require one or two initial element changes to stabilize
element life. If filter element service life is short or
differential pressure is excessive, the filter may be
undersized; refer to the sizing and selection section of
the product literature or contact your local Pall
representative.

5.5

Make sure element change labels are clean and
undamaged. Replace illegible labels with the appropriate
new labels.

6

Differential pressure devices

Reference should be made to product literature for dimensions,
operating parameters, part numbering, ordering information
and specifications. 
6.1

Differential pressure devices actuate when the element
needs changing or because of high fluid viscosity in
‘cold start’ conditions. 

6.2

If visual indicator is fitted and actuates during ‘cold start’
(red button extends 5 mm, 3/16 "), reset by depressing
the button when the normal operating temperature is
reached. If indicator actuates after resetting, replace
element. 

NOTE: Option ‘P’ visual indicator has thermal lockout and
manual reset. No signal below 0 °C (32 °F), signal above 29 °C
(80 °F).
6.3

If the electrical switch actuates (e.g. red light comes on)
during cold start, continue operating until the signal 
(red light) goes out as system warms to normal
operating temperature. This feature can be used as
'warm up' indication in operating procedures. If the
warning signal (red light) remains or appears when
system is warm, replace the filter element.

ENGLISH

6.4

Use of both positive indication (green light) and negative
indication (red light for dirty element) is recommended to
effectively monitor filter element life.

Electrical connections and ratings for all differential
pressure switch options:

110 VAC

=

4A (inductive),
4A (resistive)

220 VAC

=

4A (inductive),
4A (resistive)

28 VDC

=

3A (inductive),
5A (resistive)

48 VDC

=

1A (inductive),
1.5A (resistive)

125 VDC

=

0.25A (inductive),
0.5A (resistive)

Maximum inrush - 24 amps.
Underwriter’s lab. Inc. listed ratings of pressure switch
(Microswitch) options are:
4 amps at 250 VAC
0.25 amp resistive at 220 VDC
0.50 amp resistive at 110 VDC

Electrical differential pressure switch operation:

When preset differential pressure is exceeded continuity
switches from 'C' - 'A' to 'C' - 'B'.
When differential pressure decreases below the pre-set value,
continuity returns to 'C' - 'A'.

Figure 1 

- Switch Circuit Diagram

C
or black
or tag 2

CAUTION:
Failure to bleed the filter housing adequately will
increase the dissolved air content of the system fluid
which will shorten fluid life and may cause other
problems in the system.

A
or white
or tag 1

B
or red
or tag 3

LOW DIFFERENTIAL PRESSURE

HIGH DIFFERENTIAL PRESSURE

Summary of Contents for UH211 Series

Page 1: ...UH211 UH211 Series service instructions IMSIUH211 EN UH211 Service Instructions ENGLISH ...

Page 2: ... element removal is as follows 4 2 1 UH211C series cover service 203 mm 8 in for length 8 338 mm 13 3 in for length 13 and 508 mm 20 in for length 20 housings 4 2 2 UH211H series head service 100 mm 3 9 in for all lengths 4 2 3 The UH211 housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded differential pressure devices when ...

Page 3: ...ate new labels 6 Differential pressure devices Reference should be made to product literature for dimensions operating parameters part numbering ordering information and specifications 6 1 Differential pressure devices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start red button exten...

Page 4: ... 1 1 For UH211C series cover service Open the vent plug 7 at the top of the filter one and one half turns Open partially the blanking plug 6b in the filter head and drain fluid into a suitable waste receptacle This sequence may be long for high viscosity fluids Replace and torque tighten the blanking plug to 38 ft lb or 54Nm Unscrew and remove cover 3 from tube 2 counter clockwise when viewed from...

Page 5: ...ltered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in u...

Page 6: ...UH211 UH211 Series HIGH PRESSURE FILTERS s e r v i c e instructions 6 2 4 8 6b 3 1 Figure 2 5 7 6 Inlet Outlet Not shown on this diagram Not shown on this diagram ...

Page 7: ...UH211 UH211 Series HIGH PRESSURE FILTERS s e r v i c e instructions 7 ...

Page 8: ...d plants throughout the world For Pall representatives in your area please go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid Pall Industrial Manufactur...

Reviews: