background image

 

DICHIARAZIONE DI CONFORMITÀ UE 

EU DECLARATION OF CONFORMITY

 

 

13/14 

 

Il sottoscritto, Dr. Ing. Luigi Moretti, rappresentante il seguente costruttore 

The undersigned, Dr.Ing. Luigi Moretti, representing the following manufacturer 

 

Palazzoli S.p.A. 

25128 - BRESCIA 

– Italy – Via F. Palazzoli, 31 

Tel. +39 30 2015.1 -  Fax +39 30 2015.217 

http://www.palazzoli.it

  -  E-mail: 

[email protected]

 

 

Dichiara, sotto la propria esclusiva responsabilità, che i prodotti: 

Hereby declare, under the own sole responsibility, that the products: 

 

SWITCHGEARS in aluminum enclosure CAM-EX series 

INTERRUTTORI IN CASSETTA in alluminio serie CAM-EX 

 

With the following main features / 

Con le seguenti principali caratteristiche: 

Description / 

Descrizione 

Code / 

Codice

 

Switchgears in aluminum enclosure 

Interruttori in contenitore in alluminio 

Vedi pag. 2 delle Istruzioni di sicurezza rev. 03 (2018/12) 

See page 2 of the Safety instruction rev. 03 (2018/12) 

 

Technical Data /

 CARATTERISTICHE TECNICHE 

Insulating class /

Classe Isolamento 

Ambient Temperature range/ 

Temperatura ambiente 

Vedi pag. 2 delle Istruzioni di sicurezza rev. 03 (2018/12) 

See page 2 of the Safety instruction rev. 03 (2018/12)

 

Degree of protection(IP code) /

 Grado di protezione (codice IP)

 

IP66/IP67 (solo codice 282407EX IP65) 

Rated Voltage /

 Tensione nominale

 

110/230/400/500  Vac 

Rated Current /

 Corrente nominale

 

16 - 25 - 40 - 63 A 

Frequencies /

 Frequenze

 

50-60 Hz 

Poles /

 Poli

 

2P / 3P / 4P / 6P

 

 

 

Soddisfa i Requisiti definiti dalle seguenti Direttive / 

Satisfies the Requirements defined by following Directives: 

 

2014/34/UE 

ATEX 

 

2014/35/UE 

LVD 

2011/65/UE

 

RoHS / 

RoHS 

2012/19/UE 

RAEE / 

WEEE 

 

and that the harmonized standards and/or technical specifications listed at the following page, have been applied. 

e che sono state applicate tutte le norme armonizzate e/o specifiche tecniche indicate nella pagina seguente. 

 

Marcatura dei prodotti / 

product marking 

 

 

 

Ai sensi della Direttiva 2014/34/UE

, l’apparecchiatura è oggetto del certificato di esame UE del tipo (allegato III) N.: 

According to Directive 2014/34/EU, above mentioned equipment is subject of EU-type examination certificate (annex III) No.

 

 

TÜV IT 14 ATEX 067 X 

issued by / 

emesso da: 

TÜV ITALIA S.r.l.

 

Via Giosuè Carducci, 125 edificio 2320099 Sesto San Giovanni (MI) 
Notified Body No. / Organismo Notificato N.:

 0948 

 

Product notification no:  

Notifica di prodotto n°: 

IMQ 07 ATEXQ 001

 

 

Notified body involved in the Production control stage: 

Organismo notificato designato al controllo della Produzione:

  

IMQ - via Quintiliano, 43 (MI) ITALY - N. 0051

 

 

Brescia, 2018-12-21 

 

 

 

 

 

 

       Il Legale Rappresentante

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CAM-EX Series

Page 1: ...xed installation CAM EX Series ATEX EXECUTION INTERRUTTORI E COMMUTATORI IN CASSETTA IN LEGA DI ALLUMINIO Per installazione fissa Serie CAM EX ESECUZIONE ATEX Execution Esecuzione Group II Category 3G...

Page 2: ...l dimensions Dimensioni esterne mm 272146EX 3 16 A Ex nR IIC T5 T6 Gc Ex tb IIIC T85 C Db 125 x 185 272147EX 4 16 A 125 x 185 272246EX 3 25 A 125 x 185 272247EX 4 25 A 125 x 185 272306EX 3 40 A 125 x...

Page 3: ...in conformity with the operated parameters established by the manufacturer and ensuring a high level of protection D Equipment intended for use in the presence of combustible dust Equipment suitable f...

Page 4: ...esso un atmosfera esplosiva sotto forma di nube di polvere combustibile nell aria Zone 1 A place in which an explosive atmosphere consisting of a mixture of air and inflammable substances in the form...

Page 5: ...places with an atmosphere with the presence of combustible dust the ignition temperature of the dust is greater than the temperature indicated in the marking according to hazardous areas installation...

Page 6: ...Terminals of the switches and commutators 16 A Morsetti degli interruttori e commutatori da 16 A 1 4 Terminals of the switches and commutators 25 A Morsetti degli interruttori e commutatori da 25 A 1...

Page 7: ...t Cavo uscita mm A mm B mm C mm D mm E mm F mm 272141EX 12 18 137 5 102 92 92 77 77 272142EX 272143EX 272144EX 148 185 125 110 170 272241EX 137 5 102 92 92 77 77 272242EX 272243EX 272244EX 148 185 125...

Page 8: ...2246EX 272247EX 272306EX 16 25 16 25 148 185 125 110 170 272307EX 168 282406EX 282407EX 190 252 185 235 171 Isolator and selector switches must be installed according to this instruction These switchg...

Page 9: ...by alternate current in accordance with par 2 The switchgear must never be used with continuous current When the switchgear is used at the rated current the switchgear must be connected with maximum...

Page 10: ...spettare quanto segue Utilizzare solo cavi con guaina Utilizzare solo cavi secondo quanto previsto dal capitolo 2 del presente documento Rimuovere la guaina del cavo solo per lo stretto necessario a s...

Page 11: ...N AND DON T MAKE MAINTENANCE WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT ATTENZIONE NON APRIRE L APPARECCHIO E NON ESEGUIRE OPERAZIONI DI MANUTENZIONE QUANDO IN TENSIONE NON APRIRE E NON ESEGUIRE OPER...

Page 12: ...oblem cannot be solved contact manufacturer In caso di guasto sostituire le guarnizioni e o i pressacavi e ripetere il test In caso di nuovo esito negativo contattare il costruttore 8 3 RESTRICTED BRE...

Page 13: ...on IP code Grado di protezione codice IP IP66 IP67 solo codice 282407EX IP65 Rated Voltage Tensione nominale 110 230 400 500 Vac Rated Current Corrente nominale 16 25 40 63 A Frequencies Frequenze 50...

Page 14: ...and fuse combination units Apparecchiatura a bassa tensione Parte 3 Interruttori di manovra sezionatori interruttori di manovra sezionatori e unit combinate con fusibili Directive 2011 65 EU Direttiv...