5.
MENU
5.1 INSTALLER MENU
Access to this Menu is the RESPONSIBILITY of INSTALLATION TECHNICIANS or
EXPERT PERSONNEL, because the parameters shown, if modified, may render
the product is not suitable for the application in use.
•
To access the MENU
simultaneously
press the keys
K2
and
K4
for about 3
seconds.
•
To scroll through the parameters, use the keys
K3
and
K4
•
To view the value of the parameter and enter for modification, press the key
K2
•
To change the value, press the keys
K3
and
K4
•
To save the new value, press the key
K2
.
•
To exit without saving, press the key
K1
Press the
K1
key again to exit from the Menu or wait 60 seconds
Descrizione
Cod.
Min
Set
Max U.O.M.
Fan Activation Air Thermostat
E01
30
45
100
[°C]
SAFETY Air Thermostat
E02
80
100
140
[°C]
ALARM Air Thermostat
E03
100
120
180
[°C]
FAN SAFETY Air Thermostat
E04
100
135
180
[°C]
Valve Opening Air Thermostat
E05
20
30
140
[°C]
Valve Closing Air Thermostat
E06
20
80
140
[°C]
SERVICE output Fan Activation Air
Thermostat
E07
20
50
180
[°C]
Temperature Range for Proportional
operation
E50
20
20
100
[°C]
Fan Activation hysteresis thermostat
IE01
1
2
40
[°C]
SAFETY hysteresis thermostat
IE02
1
2
40
[°C]