004723012 - 05/05/2022
11
ITALIANO
ENGLISH
DEUTSCH
FRANÇAIS
ESPAÑOL
Conformity Declaration
Applied standards:
EN 60730-1 50081-1
EN 60730-1 A1 50081-2
TiEmme elettronica
06055 Marsciano (PG) Italy
Tel.+39.075.874.3905; Fax. +39.075.874.2239
Technical Specifications
Power supply: 230 VAC 50 Hz
± 10%
Absorption: 2 VA
Fan Output: 250 VAC 0.8A/
Fan Output: 250 VAC 1.5A Vers.
boosted
Relay Output: 250 VAC 3A
Internal Fuse: T1.6 A
Reading probes:
• NTC10K @25°C; -10 ÷ 110 °C
• NTC100K @25°C; -10 ÷ 300 °C
Mechanical
Characteristics
Material: ABS Plastic
Installation: Built in 3
Modules
Built in size:
120x80x55 mm
Degree of Protection:
IP40
Condizioni di
Installazione e Utilizzo
Conditions of Installa-
tion and Operation
Operating temperatu-
re: 0 ÷ 40° C
Storage temperature: 0
÷ 60 °C
Humidity: 85% @25°C
2.
INSTALLATION
Before carrying out any operation, make sure that the mains voltage
is switched off
•
Install the product only in dry environments and in correct climatic conditions
•
At the head of the installation, insert a bipolar switch in compliance with cur-
rent regulations
•
Avoid coupling the probe cables with power circuit cables
•
Use electrical connection cables with conductors of appropriate section and
in compliance
•
Place the probes in such a way as to correctly detect the temperatures
•
Make sure that the probe cables are not in direct/indirect contact with the fla-
me