6
Temperature control unit
GLA810 Glass
Instruction
Manual
1.
GENERAL INFORMATION
The
GLA810
Temperature control unit is an instrument for the management and control of Wood-burning Stoves and Fireplaces with Air heating.
A
1
2
Safety Standards
Carefully read the following safety notes, so as to prevent any damage and
danger to people and things.
Before performing any work on the system, follow
•
the accident prevention rules,
•
the environmental protection rules,
•
the norms of the Istituto Nazionale per l'Assicurazione contro gli
Infortuni sul Lavoro (National Institute for Insurance against
Accidents at Work),
•
accepted safety rules.
•
These instructions for use are addressed exclusively to the
technical personnel.
•
Electrical work must be performed only by qualified electrical
engineering technicians.
•
The initial commissioning of the installation must be performed by
skilled personnel or by the manufacturer or by a technician
appointed by the same.
Conformity Declaration
Applied standards:
EN 60730-1 50081-1
EN 60730-1 A1 50081-2
TiEmme elettronica
06055 Marsciano (PG) Italy Tel.+39.075.874.3905; Fax. +39.075.874.2239
Technical Specifications
Power supply: 230 VAC 50 Hz
±
10%
Absorption: 2 VA
Fan Output: 250 VAC 0.8A/
Fan Output: 250 VAC 1.5A Vers. boosted
Relay Output: 250 VAC 3A
Internal Fuse: T1.6 A
Reading probes: NTC10K @25°C; -10 ÷ 110 °C
NTC100K @25°C; -10 ÷ 300 °C
Mechanical Characteristics
Material: ABS Plastic
Installation: Built in 3 Modules
Built in size: 120x80x55 mm
Degree of Protection: IP40
Conditions of Installation and
Operation
Operating temperature: 0 ÷ 40° C
Storage temperature: 0 ÷ 60 °C
Humidity: 85% @25°C
2.
INSTALLATION
Before carrying out any operation, make sure that the mains voltage is switched off
•
Install the product only in dry environments and in correct climatic conditions
•
At the head of the installation, insert a bipolar switch in compliance with current regulations
•
Avoid coupling the probe cables with power circuit cables
•
Use electrical connection cables with conductors of appropriate section and in compliance
•
Place the probes in such a way as to correctly detect the temperatures
•
Make sure that the probe cables are not in direct/indirect contact with the flame
3.
ELECTRICAL CONNECTIONS
FUSE
T1,6A
12 11 10 9
S1
S2
1
5 6 7
2 3 4
LINEA
230Vac
L-
O
N
L
N
8
N
VENT
230Vac
SERV
IN
SCI
All the control Outputs and probe Inputs are controlled
automatically according to the type/diagram of the chosen
Installation.
Fig. 2 - Electric connections
Initials
Terminals
Device
Characteristics
IN
PU
TS
LINE
1 - 2
Mains Power Supply
230 Vac 50 Hz
±
10%
IN SCI
3
–
4
Spark Consent
Input 230 VAC 50 Hz
±
10%
S1
9
–
10
Air Temperature Probe
Range of operation: -10°C
÷
180 °C
NTC 100K Measurement: -10
÷ 300
°C
±
1°C
S2
11
–
12
Room Temperature Probe /
Room Temp. Thermostat
Range of operation: -10°C
÷
125 °C
NTC 10K Measurement: -10
÷
110 °C
±
1°C
O
U
TP
U
T
S
VENT
5
–
6
Fan
230 VAC 0.8A
SERV
7 - 8
Service Output
Free contacts: COM. (7) - N.O. (8)